Institutional experience with SRS VMAT planning for multiple cranial metastases

نویسندگان

  • Åse Ballangrud
  • Li Cheng Kuo
  • Laura Happersett
  • Seng Boh Lim
  • Kathryn Beal
  • Yoshiya Yamada
  • Margie Hunt
  • James Mechalakos
چکیده

BACKGROUND AND PURPOSE This study summarizes the cranial stereotactic radiosurgery (SRS) volumetric modulated arc therapy (VMAT) procedure at our institution. MATERIALS AND METHODS Volumetric modulated arc therapy plans were generated for 40 patients with 188 lesions (range 2-8, median 5) in Eclipse and treated on a TrueBeam STx. Limitations of the custom beam model outside the central 2.5 mm leaves necessitated more than one isocenter pending the spatial distribution of lesions. Two to nine arcs were used per isocenter. Conformity index (CI), gradient index (GI) and target dose heterogeneity index (HI) were determined for each lesion. Dose to critical structures and treatment times are reported. RESULTS Lesion size ranged 0.05-17.74 cm3 (median 0.77 cm3 ), and total tumor volume per case ranged 1.09-26.95 cm3 (median 7.11 cm3 ). For each lesion, HI ranged 1.2-1.5 (median 1.3), CI ranged 1.0-2.9 (median 1.2), and GI ranged 2.5-8.4 (median 4.4). By correlating GI to PTV volume a predicted GI = 4/PTV0.2 was determined and implemented in a script in Eclipse and used for plan evaluation. Brain volume receiving 7 Gy (V7 Gy ) ranged 10-136 cm3 (median 42 cm3 ). Total treatment time ranged 24-138 min (median 61 min). CONCLUSIONS Volumetric modulated arc therapy provide plans with steep dose gradients around the targets and low dose to critical structures, and VMAT treatment is delivered in a shorter time than conventional methods using one isocenter per lesion. To further improve VMAT planning for multiple cranial metastases, better tools to shorten planning time are needed. The most significant improvement would come from better dose modeling in Eclipse, possibly by allowing for customizing the dynamic leaf gap (DLG) for a special SRS model and not limit to one DLG per energy per treatment machine and thereby remove the limitation on the Y-jaw and allow planning with a single isocenter.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Volumetric Modulated Arc Therapy for Spine Radiosurgery: Superior Treatment Planning and Delivery Compared to Static Beam Intensity Modulated Radiotherapy

PURPOSE Spine stereotactic radiosurgery (SRS) delivers an accurate and efficient high radiation dose to vertebral metastases in 1-5 fractions. We aimed to compare volumetric modulated arc therapy (VMAT) to static beam intensity modulated radiotherapy (IMRT) for spine SRS. METHODS AND MATERIALS Ten spine lesions of previously treated SRS patients were planned retrospectively using both IMRT an...

متن کامل

Volumetric intensity modulated arc therapy for stereotactic body radiosurgery in oligometastatic breast and gynecological cancers: feasibility and clinical results.

In the present study, the preliminary results of the first stereotactic body radiosurgery (SRS) experience with volumetric intensity modulated arc therapy (VMAT) in oligometastatic breast and recurrent gynecological tumors (OBRGT) are reported in terms of feasibility, toxicity and efficacy. Patients were treated in a head-first supine treatment position on a customized body frame immobilization...

متن کامل

Single fraction stereotactic radiosurgery for multiple brain metastases

Introduction Due to the neurocognitive side effects of whole brain radiation therapy (WBRT), stereotactic radiosurgery (SRS) is being used with increasing frequency. The use of SRS is expanding for patients with multiple (>4) brain metastases (BM). This study summarizes our institutional experience with single-fraction, linear-accelerator-based SRS for multiple BM. Methods and materials All p...

متن کامل

Linac-based VMAT radiosurgery for multiple brain lesions: comparison between a conventional multi-isocenter approach and a new dedicated mono-isocenter technique

BACKGROUND Linac-based stereotactic radiosurgery or fractionated stereotactic radiotherapy (SRS/FSRT) of multiple brain lesions using volumetric modulated arc therapy (VMAT) is typically performed by a multiple-isocenter approach, i.e. one isocenter per lesion, which is time-demanding for the need of independent setup verifications of each isocenter. Here, we present our initial experience with...

متن کامل

Evaluation of a dedicated brain metastases treatment planning optimization for radiosurgery: a new treatment paradigm?

PURPOSE To investigate the feasibility of a novel dedicated treatment planning solution, to automatically target multiple brain metastases with a single isocenter and multiple inversely-optimized dynamic conformal arcs (DCA), and to benchmark it against the well-established multiple isocenter DCA (MIDCA) and volumetric modulated arc therapy (VMAT) approaches. MATERIAL AND METHODS Ten previous...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 19  شماره 

صفحات  -

تاریخ انتشار 2018