The Colorimetric Estimation of the Hydrogen Ion Concentration of Blood.*

نویسندگان

  • VICTOR C. MYERS
  • EDWARD MUNTWYLER
چکیده

With the introduction of Cullen’s calorimetric method (1) of estimating the hydrogen ion concentration of blood serum or plasma, it seemed possible for every laboratoryto have a methodemploying minimum material and apparatus and yet secure reliable results. It is generally conceded that the results obtained by the method on normal human plasma or serum agree very well with the true pH as determined electrometrically. Recently, however, considerable doubt has arisen as to its applicability to abnormal samples. Austin, Stadie, and Robinson (2) observed considerable variation, under pathological conditions in man and in the dog under normal and experimental conditions, in the difference between the calorimetric reading of the diluted serum or plasma at 20” or at 38” and the true pH of the undiluted sample at 38”. They conclude that for use with pathological sera, or under changing experimental conditions, the C or the H correction must be determined on each serum if the calorimetric readings made at 20” or 38” are to be relied upon, and have outlined a procedure for doing this. Hastings, Neill, Morgan, and Binger (3), studying the blood reaction in cases of pneumonia, find it better to use 0.27 as the correction factor instead of 0.22. Cullen, Keeler, and

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A New Colorimetric Azo-azomethine Probe for Fluoride Ion Detection Based on the Proton Transfer Signaling Mode: Real-life Applications

Four novel receptors were designed and synthesized for colorimetric detection of F− ions. The introduction of four electron withdrawing groups into the backbone of the receptors makes the two phenolic groups efficient hydrogen bonding sites. The binding properties of receptors with anions were examined for the first time by UV–Vis, 1H NMR and fluorescence spectroscopies. The addition of F− resu...

متن کامل

Adsorption of Cr(III) and Mg(II) from Hydrogen Peroxide Aqueous Solution by Amberlite IR-120 Synthetic Resin

In concentration of hydrogen peroxide, first, the solution should be quite pure, and then, it concentrate with methods such as vacuum distillation and cooling crystallization, because impurities in the hydrogen peroxide solution in high concentrations are causing decomposition of this substance; that is very dangerous. The purpose of this article is separation of chromium and magne...

متن کامل

Naphthalene-based Azo-azomethine Chemosensor: Naked Eye Detection of Fluoride in Semi-aqueous Media

A new azo-azomethine chemosensor containing active phenolic sites, H2L, has been designed and synthesized for rapid detection of inorganic fluoride over the other anions, such as Clˉ, Brˉ, Iˉ, AcOˉ, H2PO4ˉ, NO3ˉ, N3ˉ in DMSO/water (90/10) media. The 1H NMR titration revealed that the colorimetric response was considered to be the direct consequence of hydrogen-bond formation between phenolic gr...

متن کامل

Colorimetric Determination of the Hydrogen Ion Concentration in Small Quantities of Solution.*

The hydrogen ion concentration (1) of many solutions and of culture media is readily determined by means of buffer solutions and suitable indicators. The usual procedure, in determining calorimetrically the hydrogen ion concentration, requires a considerable volume of solution. Frequently the quantity of solution available in experiments upon plants or animals is extremely limited in amount. It...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2003