Pitfalls in TAMVI: experience with the repositionable Lotus® Valve System

نویسندگان

  • Paul P Heinisch
  • Fabien Praz
  • Bernhard Winkler
  • Stephan Windecker
  • Christoph Huber
  • Thierry Carrel
چکیده

BACKGROUND Simultaneous transapical implantation of transcatheter heart valves in the native mitral and aortic position may be considered as an alternative to surgical valve replacement in high-risk patients presenting with combined valve disease. CASE PRESENTATION A 59-year-old female with severe aortic stenosis, severe mitral stenosis with mild mitral insufficiency, persistent atrial fibrillation, severe chronic obstructive pulmonary disease and NYHA class of IV was evaluated by our interdisciplinary heart team. Due to the calculated Euroscore II, logistic Euroscore with 10% and 17% a decision was made towards a transapical TAVI approach. The implantation of a Sapien 3 (Edwards Lifesciences) valve in the aortic position was performed and the perioperative TEE showed a good result. The preoperative imaging revealed a narrow LVOT with risk for post interventional left ventricular outflow tract obstruction. Accordingly, it was decided against the use of balloon-expanding valves for the mitral valve position in the interdisciplinary team, as it is not repositionable. Instead, it was decided for the use of a Lotus (Boston Scientific) valve, as it is repositionable and therefore possible to retract in case of LVOT obstruction. In the present case of double valve intervention, the implantation attempt of a fully repositionable transcatheter heart valve into the native mitral annulus resulted in acute LVOT obstruction requiring immediate removal of the device. The patient was extubated and experienced uneventful postoperative recovery. CONCLUSIONS The case shows that improved preoperative work-up is necessary for better prediction of significant LVOT obstruction following transcatheter mitral valve implantation. In borderline cases, the use of a fully repositionable device is preferred.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Repositionable Versus Balloon‐Expandable Devices for Transcatheter Aortic Valve Implantation in Patients With Aortic Stenosis

BACKGROUND The safety and effectiveness of the fully repositionable LOTUS valve system as compared with the balloon-expandable Edwards SAPIEN 3 prosthesis for the treatment of aortic stenosis has not been evaluated to date. METHODS AND RESULTS All patients undergoing transcatheter aortic valve implantation with the Edwards SAPIEN 3 or the LOTUS valve system were included into the Swiss Transc...

متن کامل

The safety of introducing a new generation TAVR device: one departments experience from introducing a second generation repositionable TAVR

BACKGROUND In the evolving field of transcatheter aortic valve replacements a new generation of valves have been introduced to clinical practice. With the complexity of the TAVR procedure and the unique aspects of each TAVR device, there is a perceived risk that changing or adding a new valve in a department could lead to a worse outcome for patients, especially during the learning phase. The o...

متن کامل

Outcome With the Repositionable and Retrievable Boston Scientific Lotus Valve Compared With the Balloon-Expandable Edwards Sapien 3 Valve in Patients Undergoing Transfemoral Aortic Valve Replacement.

BACKGROUND New generation devices for transfemoral aortic valve replacement were optimized on valve positioning and reduction of residual aortic regurgitation. We compared 30-day, 12-month, and 24-month outcomes of the Boston Scientific Lotus valve (Lotus) and the balloon-expandable Edwards Sapien 3 (ES3) valve. Primary end point was all-cause mortality or disabling stroke within 12 months. M...

متن کامل

1-Year Outcomes With the Fully Repositionable and Retrievable Lotus Transcatheter Aortic Replacement Valve in€120 High-Risk Surgical Patients With Severe Aortic Stenosis

OBJECTIVES This analysis presents the first report of 1-year outcomes of the 120 patients enrolled in the REPRISE II (Repositionable Percutaneous Placement of Stenotic Aortic Valve Through Implantation of Lotus Valve System– Evaluation of Safety and Performance) study. BACKGROUND The fully repositionable and retrievable Lotus Valve (Boston Scientific, Marlborough, Massachusetts) was designed to...

متن کامل

Transcatheter Aortic Valve Replacement Using the Repositionable LOTUS Valve: United Kingdom Experience.

OBJECTIVES This study sought to present the U.K. experience to date with the second-generation LOTUS bioprosthesis (Boston Scientific, Natick, Massachusetts). BACKGROUND First-generation transcatheter aortic valves have limitations. Second-generation repositionable valves may improve on some of those limitations. METHODS Prospectively collected data relating to procedural and in-hospital ou...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 12  شماره 

صفحات  -

تاریخ انتشار 2017