Tidal volume delivery from ICU ventilators at BTPS conditions: a bench study.

نویسندگان

  • Paul Duchateau
  • Claude Guérin
چکیده

BACKGROUND Even though it is not a common practice, an external filter to the expiratory limb of the breathing circuit may protect the expiratory valve from water saturation in case of nebulization, or from the environment in case of lung infection with multi-drug-resistant micro-organisms or H1N1 influenza. METHODS We added an external filter to the expiratory limb and measured tidal volume (VT) from 6 ICU ventilators: 2 with built-in expiratory filter (Avea, Puritan Bennett 840), and 4 without (Engström Carestation, Evita XL, Evita V500, and Servo-i), set in volume controlled mode, at BTPS (body temperature and pressure saturated) condition, with a heated humidifier and a lung model (compliance 16 mL/cm H2O, resistance 20 cm H2O/L/s) placed inside a neonatal incubator. The temperature was targeted at 37°C for both the heated humidifier and the incubator. The setup was run continuously for 24 hours. In the latter 4 ICU ventilators, a Hygrobac or Sterivent S external filter was placed upstream from the expiratory valve for an additional 24-hour period for each. At the end of this period, VT was measured at 4 nominal VT values (300, 400, 500, and 800 mL) with a pneumotachograph. The volume error computed from the ratio of set to measured VT (% set VT) was the primary end point. RESULTS In these warm and wet conditions, volume error averaged 96 ± 3% for Avea, 100 ± 7% for Puritan Bennett 840, 90 ± 2% for Evita XL, 100 ± 7% for Evita V500, 105 ± 2% for Servo-i, and 108 ± 4% for Engström Carestation (P < .001). With the Hygrobac the values were 93 ± 1% for Evita XL, 94 ± 4% for Evita V500, 110 ± 4% for Servo-i, and 99 ± 2% for Engström Carestation (P < .001). With the Sterivent the corresponding values were 95 ± 2%, 105 ± 2%, 112 ± 5%, and 98 ± 2%, respectively (P < .001). CONCLUSIONS In BTPS condition, volume error differed substantially across ICU ventilators for VT delivery, with further significant changes occurring after addition of a filter at the distal expiratory limb.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Near-infrared spectroscopy with vascular occlusion test may not be the adequate tool to explore microcirculation in pulmonary arterial hypertension.

essentials of respiratory care, 4th edition. St. Louis:Mosby Elsevier; 2005:103. 13. L’Her E, Roy A. Bench tests of simple, handy ventilators for pandemics: performance, autonomy, and ergonomy. Respir Care 2011;56(6):751-760. 14. Lyazidi A, Thille AW, Carteaux G, Galia F, Brochard L, Richard JC. Bench test evaluation of volume delivered by modern ICU ventilators during volume-controlled ventila...

متن کامل

Evaluation of ventilators used during transport of critically ill patients: a bench study.

OBJECTIVE To evaluate the most recent transport ventilators' operational performance regarding volume delivery in controlled mode, trigger function, and the quality of pressurization in pressure support mode. METHODS Eight recent transport ventilators were included in a bench study in order to evaluate their accuracy to deliver a set tidal volume under normal resistance and compliance conditi...

متن کامل

Bench-test comparison of 26 emergency and transport ventilators

INTRODUCTION Numerous emergency and transport ventilators are commercialized and new generations arise constantly. The aim of this study was to evaluate a large panel of ventilators to allow clinicians to choose a device, taking into account their specificities of use. METHODS This experimental bench-test took into account general characteristics and technical performances. Performances were ...

متن کامل

RESPIRATION AND THE AIRWAY Delivery of tidal volume from four anaesthesia ventilators during volume-controlled ventilation: a bench study

Editor’s key points † This study investigated the accuracy of delivered tidal volume in four new ventilators under different conditions. † Set and delivered tidal volumes differed when compliance and resistance were changed, although the effect of fresh gas flow was less. † Some of the new ventilators tested were more accurate than others. † The clinical significance of these findings is uncert...

متن کامل

Delivery of tidal volume from four anaesthesia ventilators during volume-controlled ventilation: a bench study.

BACKGROUND Tidal volume (V(T)) must be accurately delivered by anaesthesia ventilators in the volume-controlled ventilation mode in order for lung protective ventilation to be effective. However, the impact of fresh gas flow (FGF) and lung mechanics on delivery of V(T) by the newest anaesthesia ventilators has not been reported. METHODS We measured delivered V(T) (V(TI)) from four anaesthesia...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Respiratory care

دوره 58 4  شماره 

صفحات  -

تاریخ انتشار 2013