Impact of percutaneous device implantation for closure of patent foramen ovale on valve insufficiencies.

نویسندگان

  • Jochen Wöhrle
  • Matthias Kochs
  • Jochen Spiess
  • Thorsten Nusser
  • Vinzenz Hombach
  • Nico Merkle
چکیده

BACKGROUND In patients with percutaneous device implantation for closure of patent foramen ovale (PFO), a 10% incidence of new or worsened aortic regurgitation within 12 months has been reported with echocardiography. Cardiac magnetic resonance imaging is a powerful noninvasive tool to quantify volume and fraction of valve insufficiencies. We studied the acute and long-term impact of percutaneous device implantation for PFO closure on valve insufficiencies in cardiac magnetic resonance imaging. METHODS AND RESULTS Sequential cardiac magnetic resonance imaging studies were performed in 102 patients with cryptogenic ischemic events. Cardiac magnetic resonance imaging was performed before PFO closure, the day after device implantation, and at 12 months of follow-up. There was no difference in volumetric and hemodynamic parameters before PFO closure compared with 12 months of follow-up. With a cutoff for relevant regurgitation fraction of 5%, there were no statistically significant differences in regurgitation fraction of the semilunar and atrioventricular valves. The median fraction of aortic valve insufficiency was 3.9% (interquartile range [IQR] 2.0% to 5.1%) before PFO closure, 5.4% (IQR 4.1% to 5.9%) after device implantation, and 4.3% (IQR 3.3% to 6.0%) at 12 months of follow-up. The size and type of the occluder had no impact on aortic valve insufficiency. Median regurgitation fraction for the pulmonary valve was 3.6% (IQR 2.4% to 6.7%) before intervention, 7.3% (IQR 5.1% to 8.2%) after occluder implantation and 5.8% (IQR 4.8% to 7.4%) at 12 months of follow-up. Values for the mitral valve were 3.1% (IQR 1.4% to 6.0%), 5.5% (IQR 3.5% to 7.3%), and 3.8% (IQR 1.5% to 7.9%) and for the tricuspid valve were 5.4% (IQR 0.1% to 8.8%), 5.8% (IQR 1.4% to 9.2%), and 6.0% (IQR 1.1% to 8.4%), respectively. CONCLUSIONS Percutaneous PFO closure with device implantation has no impact on valve insufficiencies as determined by cardiac magnetic resonance imaging.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Heart Carcinoid Disease with Patent Foramen Ovale Treated by Mini Sternotomy

This case report was an attempt to present the importance of diagnostic echocardiography and closure of a patent foramen ovale in carcinoid heart disease. Herein, we present a case of a 48-year-old woman with a carcinoid metastasis presenting with tricuspid regurgitation, pulmonic stenosis, patent foramen ovale, and borderline left ventricular ejection fraction on an echocardiogram. Surgical in...

متن کامل

CONGENITAL HEART DISEASE Percutaneous closure of patent foramen ovale: impact of device design on safety and efficacy

Objective: To compare the safety and efficacy of percutaneous closure of patent foramen ovale (PFO) with the Amplatzer PFO occluder (Amplatzer) or the PFO STAR device (STAR) in patients with presumed paradoxical embolism. Methods: Implantation characteristics, procedural complications, residual shunt, and recurrence of thromboembolic events were recorded prospectively in 100 consecutive patient...

متن کامل

Percutaneous closure of patent foramen ovale: impact of device design on safety and efficacy.

OBJECTIVE To compare the safety and efficacy of percutaneous closure of patent foramen ovale (PFO) with the Amplatzer PFO occluder (Amplatzer) or the PFO STAR device (STAR) in patients with presumed paradoxical embolism. METHODS Implantation characteristics, procedural complications, residual shunt, and recurrence of thromboembolic events were recorded prospectively in 100 consecutive patient...

متن کامل

Myocarditis due to pandemic influenza A (H1N1).

1. Cruz-Gonzalez I, Solis J, Inglessis-Azuaje I, Palacios IF. Foramen oval permeable: situación actual. Rev Esp Cardiol. 2008;61:738-51. 2. Wahl A, Meier B, Haxel B, Nedeltchev K, Arnold M, Eicher E, et al. Prognosis after percutaneous closure of patent foramen ovale for paradoxical embolism. Neurology. 2001;57:1330-2. 3. Windecker S, Wahl A, Chatterjee T, Garachemani A, Eberli FR, Seiler C, et...

متن کامل

Usefulness of percutaneous closure of patent foramen ovale for hypoxia.

We report a patient with hypoxia secondary to a right-to-left shunt through a patent foramen ovale, following aortic root, valve, and arch replacement due to an aortic dissection in the setting of the Marfan syndrome. Following the operation, he failed extubation twice due to hypoxia. An extensive workup revealed a right-to-left shunt previously not seen. The patent foramen ovale was closed usi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Circulation

دوره 119 23  شماره 

صفحات  -

تاریخ انتشار 2009