Determination of plasma procainamide and N-acetylprocainamide concentration by high-pressure liquid chromatography.

نویسندگان

  • J S Dutcher
  • J M Strong
چکیده

We describe a routine method for determining concentrations of the antiarrhythmic drug procainamide and its active metabolite, N-acetylprocainamide, in plasma. A simple extraction of 1.0 ml of plasma is followed by separation and chromatographic analysis by use of a column containing microparticulate silica. p-nitro-N-(2-diethylaminoethyl)benzamide hydrochloride was synthesized and used as the internal standard. Total chromatographic time is only 7 min. The day-to-day CV during three months of daily use was less than 4% of the mean for each compound, and we saw no deterioration in column performance during this time. Phenobarbital, phenytoin, lidocaine, primidone, methsuximide, quinidine, and their metabolites do not interfere.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Excretionof EndogenousDigoxin-likeImmunoreactiveFactors in Human Urine Is a Functionof Unne Flow Rate

procainamide and N-acetylprocainamide in plasma or serum by high-performance liquid chromatography. Clin Chem 197723:7058. 10. Lai C, Kaniath BL, Look ZM, Yacobi A. Determination of procainamide and N-acetylprocainamide in biological fluids by high-pressure liquid chromatography. J Pharm Sci 1980;69:982-4. 11. Walberg CB, Wan SH. Clinical evaluation of EMIT procainamide and N-acetylprocainainid...

متن کامل

Improved liquid-chromatographic determination of propranolol in plasma, with fluorescence detection.

We describe an analysis for propranolol in plasma, with use of reversed-phase "high-pressure" liquid chromatography and fluorescence detection. Pronethalol is used as the internal standard. The procedure, which involves extraction into an organic solvent, evaporation, and clean-up by micro-scale back extraction from hexane into an aqueous phase, is specific and sensitive. The detection limit is...

متن کامل

Lighter than Water Dispersive Liquid-liquid Microextraction Coupled with High Performance Liquid Chromatography for Determination of Cholecalciferol and Calcifediol from Plasma

In this study, a dispersive liquid–liquid microextraction method using an extraction solvent lighter than water has been developed for the extraction and preconcentration of cholecalciferol and calcifediol from plasma samples followed by high performance liquid chromatography determination. Initially, acetonitrile and sodium chloride (NaCl) are added into the plasma as an extraction solvent and...

متن کامل

Simultaneous quantitation of quinidine, procainamide, and N-acetylprocainamide in serum by gas-liquid chromatography with a nitrogen-phosphorus selective detector.

We describe a single-run method for quantitating quinidine, procainamide, and N-acetylprocainamide, involving gas-liquid chromatography with a nitrogen-phosphorus selective detector. Within-run precision (CV) was 3% (x = 2 mg/L, n = 20), 6.9% (x = 4 mg/L, n = 10), and 1.5% (x = 8 mg/L, n = 8) for quinidine; 7.7% (x = 4 mg/L, n = 14), 1.6% (x = 8 mg/L, n = 16), and 2.3% (x = 12 mg/L, n = 12) for...

متن کامل

Fluorometric assay for N-acetylprocainamide.

We describe a simple, rapid fluorometric assay for separate quantitative analysis of procainamide and N-acetylprocainamide in mixtures. The effective lenear range (fluorescence vs. concentration) in serum is 0.1 to 10.0 mg/liter, regardless of the ratio (by weight) of the two drugs from 1:10 to 10:1. Analytical recoveries by the extraction method used were 100.0 +/- 3.0% and 98.0 +/- 4.0%, resp...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Clinical chemistry

دوره 23 7  شماره 

صفحات  -

تاریخ انتشار 1977