Slow and fast lung compartments in cystic fibrosis measured by nitrogen multiple-breath washout.

نویسندگان

  • P M Gustafsson
  • P D Robinson
  • M Gilljam
  • A Lindblad
  • B K Houltz
چکیده

Imaging studies describe significant ventilation defects across a wide range of cystic fibrosis (CF) related lung disease severity. These are unfortunately poorly reflected by phase III slope analysis-derived Scond and Sacin from multiple-breath washout (MBW). Methodology extending previous two-lung compartment model-based analysis is presented describing size and function of fast- and slow-ventilating lung compartments from nitrogen (N2) MBW and correlation to obstructive lung disease severity. In 37 CF subjects (forced expiratory volume in 1 s [FEV1] mean [SD] 84.8 [19.9] % predicted; abnormal lung clearance index [LCI] in 36/37, range 7.28-18.9) and 74 matched healthy controls, volume and specific ventilation of both fast and slowly ventilated lung compartments were derived from N2-based MBW with commercial equipment. In healthy controls lung emptying was characterized by a large compartment constituting 75.6 (8.4)% of functional residual capacity (FRC) with a specific ventilation (regional alveolar tidal volume/regional lung volume) of 13.9 (3.7)% and a small compartment with high specific ventilation (48.4 [15.7]%). In CF the slowly ventilated lung compartment constituted 51.9(9.1)% of FRC, with low specific ventilation of 5.3 (2.4)%. Specific ventilation of the slowly ventilated lung compartment showed stronger correlation with LCI (r2 = 0.70, P < 0.001) vs. Sacin (r2 = 0.44, P < 0.001) or Scond (no significant correlation). Overventilation of the fast lung compartment was no longer seen in severe CF lung disease. Magnitude and function of under- and overventilated lung volumes can be derived from routine N2 MBW in CF. Reported values agree with previous modelling-derived estimates of impaired ventilation and offer improved correlation to disease severity, compared with SnIII analysis.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Moment ratio analysis of multiple breath nitrogen washout in infants with lung disease.

Measurement of lung volumes at end expiratory level and assessment of ventilation inhomogeneity is important for respiratory management in infants with lung disease. This study compared multiple breath nitrogen washout was compared with body plethysmography to measure functional residual capacity in infants and assessed ventilation inhomogeneity using mean dilution numbers and alveolar based ga...

متن کامل

Evaluation of the Impact of Alveolar Nitrogen Excretion on Indices Derived from Multiple Breath Nitrogen Washout

BACKGROUND A large body of evidence has now accumulated describing the advantages of multiple breath washout tests over conventional spirometry in cystic fibrosis (CF). Although the majority of studies have used exogenous sulphur hexafluoride (SF6) as the tracer gas this has also led to an increased interest in nitrogen washout tests, despite the differences between these methods. The impact of...

متن کامل

Multiple Breath Nitrogen Washout: A Feasible Alternative to Mass Spectrometry

BACKGROUND The lung clearance index (LCI), measured by multiple breath washout (MBW), reflects global ventilation inhomogeneity and is a sensitive marker of early cystic fibrosis (CF) lung disease. Current evidence is based on a customized mass spectrometry system that uses sulfur hexafluoride (SF6) as a tracer gas, which is not widely available. Nitrogen (N2) washout may be better suited for c...

متن کامل

A new double-tracer gas single-breath washout to assess early cystic fibrosis lung disease.

In cystic fibrosis (CF), tests for ventilation inhomogeneity are sensitive but not established for clinical routine. We assessed feasibility of a new double-tracer gas single-breath washout (SBW) in school-aged children with CF and control subjects, and compared SBW between groups and with multiple-breath nitrogen washout (MBNW). Three SBW and MBNW were performed in 118 children (66 with CF) us...

متن کامل

Multiple-breath washout measurements can be significantly shortened in children.

Multiple-breath washout (MBW)-derived lung clearance index (LCI) is a sensitive measure of ventilation inhomogeneity in patients with cystic fibrosis (CF), but LCI measurement is time consuming. We systematically assessed ways to shorten LCI measurements. In 68 school-aged children (44 with mild CF lung disease) three standard nitrogen (N2) MBWs were applied. We assessed repeatability and diagn...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of applied physiology

دوره 117 7  شماره 

صفحات  -

تاریخ انتشار 2014