Fast 2D Imaging for Distortion Correction Near Metal Implants

نویسندگان

  • Brian A Hargreaves
  • Valentina Taviani
  • Daehyun Yoon
چکیده

Purpose: Multispectral imaging (MSI) approaches such as SEMAC, MAVRIC, MAVRIC-SL and others have shown promise for artifact-reduced imaging near metal [1-3]. These methods all combine multiple 3D images, each from a separately excited region (frequency bands in MAVRIC, distorted slices in SEMAC). The longer scan times of these approaches can be mitigated using reduced-excitation-region approaches using varied 90°/180° pulse bandwidths in combination with SEMAC or MAVRIC [4,5]. Here we investigate a fast, distortion-free 2D imaging alternative that offers considerable flexibility when the number of slices is limited (e.g. for localization), or when off-resonance variation is small (near smaller devices).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Adaptive Slice Encoding for Metal Artifact Correction

Introduction: Metallic implants can cause moderate or severe distortion artifacts in MR images depending on the shape, size, composition and orientation of the implant. Recentlyproposed methods correct image distortion due to susceptibility shifts near metallic implants by using excitation of limited bandwidths [1] or limited spatial slices [2], both followed by 3D imaging. Here we demonstrate ...

متن کامل

Fat-Suppressed and Distortion-Corrected MRI Near Metallic Implants

Introduction: The use of orthopedic implants including joint replacements and fixation devices is increasingly common, necessitating follow-up evaluation to assess possible complications such as loosening or infection. Due to metal-induced distortion and other artifacts on conventional MRI, follow-up is often limited to Xray images. With additional encoding and parallel imaging, MR images with ...

متن کامل

Artifact reduction techniques in Cone Beam Computed Tomography (CBCT) imaging modality

Introduction: Cone beam computed tomography (CBCT) was introduced and became more common based on its low cost, fast image procedure rate and low radiation dose compared to CT. This imaging modality improved diagnostic and treatment-planning procedures by providing three-dimensional information with greatly reduced level of radiation dose compared to 2D dental imaging modalitie...

متن کامل

New approach for calibration of pixelated scintillation detectors of intraoperative gamma cameras

Introduction:SURGEOSIGHT is a dedicated intra-operative hand-held gamma camera designed and manufactured by our team to be used for lymphoscintigraphy. Although conventional gamma cameras are widely used, they lack the capability of the sentinel lymph node (SLN) imaging in the operation room. Like conventional gamma cameras it is necessary to calibrate SURGEOSIGHT for linearity...

متن کامل

SEMAC: Slice Encoding for Metal Artifact Correction in MRI.

Magnetic resonance imaging (MRI) near metallic implants remains an unmet need because of severe artifacts, which mainly stem from large metal-induced field inhomogeneities. This work addresses MRI near metallic implants with an innovative imaging technique called "Slice Encoding for Metal Artifact Correction" (SEMAC). The SEMAC technique corrects metal artifacts via robust encoding of each exci...

متن کامل