Electrochemical Genotoxicity Assay Based on a SOS/umu Test Using Hydrodynamic Voltammetry in a Droplet

نویسندگان

  • Hideki Kuramitz
  • Kazuto Sazawa
  • Yasuaki Nanayama
  • Noriko Hata
  • Shigeru Taguchi
  • Kazuharu Sugawara
  • Masami Fukushima
چکیده

The SOS/umu genotoxicity assay evaluates the primary DNA damage caused by chemicals from the β-galactosidase activity of S. typhimurium. One of the weaknesses of the common umu test system based on spectrophotometric detection is that it is unable to measure samples containing a high concentration of colored dissolved organic matters, sediment, and suspended solids. However, umu tests with electrochemical detection techniques prove to be a better strategy because it causes less interference, enables the analysis of turbid samples and allows detection even in small volumes without loss of sensitivity. Based on this understanding, we aim to develop a new umu test system with hydrodynamic chronoamperometry using a rotating disk electrode (RDE) in a microliter droplet. PAPG when used as a substrate is not electroactive at the potential at which PAP is oxidized to p-quinone imine (PQI), so the current response of chronoamperometry resulting from the oxidation of PAP to PQI is directly proportional to the enzymatic activity of S. typhimurium. This was achieved by performing genotoxicity tests for 2-(2-furyl)-3-(5-nitro-2-furyl)-acrylamide (AF-2) and 2-aminoanthracene (2-AA) as model genotoxic compounds. The results obtained in this study indicated that the signal detection in the genotoxicity assay based on hydrodynamic voltammetry was less influenced by the presence of colored components and sediment particles in the samples when compared to the usual colorimetric signal detection. The influence caused by the presence of humic acids (HAs) and artificial sediment on the genotoxic property of selected model compounds such as 4-nitroquinoline-N-oxide (4-NQO), 3-chloro-4-(dichloromethyl)-5-hydroxy-2(5H)-furanone (MX), 1,8-dinitropyrene (1,8-DNP) and 1-nitropyrene (1-NP) were also investigated. The results showed that the genotoxicity of 1-NP and MX changed in the presence of 10 mg∙L-1 HAs. The genotoxicity of tested chemicals with a high hydrophobicity such as 1,8-DNP and 1-NP were decreased substantially with the presence of 1 g∙L-1 sediment. This was not observed in the case of genotoxins with a low log K(ow) value.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparative cytotoxic and genotoxic potential of 13 drinking water disinfection by-products using a microplate-based cytotoxicity assay and a developed SOS/umu assay Shao-hui Zhang1,2,3, Dong-yue Miao1,2, Li Tan1,2, Ai-lin Liu1,2,* and Wen-qing Lu1,2

The implications of disinfection by-products (DBPs) present in drinking water are of public health concern because of their potential mutagenic, carcinogenic and other toxic effects on humans. In this study, we selected 13 main DBPs found in drinking water to quantitatively analyse their cytotoxicity and genotoxicity using a microplate-based cytotoxicity assay and a developed SOS/umu assay in S...

متن کامل

Hydrodynamic Voltammetry as a Rapid and Simple Method for Evaluating Soil Enzyme Activities

Soil enzymes play essential roles in catalyzing reactions necessary for nutrient cycling in the biosphere. They are also sensitive indicators of ecosystem stress, therefore their evaluation is very important in assessing soil health and quality. The standard soil enzyme assay method based on spectroscopic detection is a complicated operation that requires the removal of soil particles. The purp...

متن کامل

Assessment of genotoxic activity of petroleum hydrocarbon-bioremediated soil.

The relationship between toxicity and soil contamination must be understood to develop reliable indicators of environmental restoration for bioremediation. Two bacterial rapid bioassays, SOS chromotest and the umu test with and without metabolic activation (S-9 mixture), were used to evaluate the genotoxicity of petroleum hydrocarbon-contaminated soil following bioremediation treatment. The soi...

متن کامل

Evaluation of photo-genotoxicity using the umu test in strains with a high sensitivity to oxidative DNA damage.

Six compounds known to be photo-genotoxic were assayed with the photo-irradiated 96-well umu test system using the original Salmonella strain TA1535/pSK1002 as well as the newly developed strains NM8001 and NM8021. The latter two strains were obtained by introducing the pSK1002 plasmid into strains YG3001 and YG3021. These strains are highly sensitive to oxidative DNA damage owing to the deleti...

متن کامل

A biosensor for environmental genotoxin screening based on an SOS lux assay in recombinant Escherichia coli cells.

A genetically controlled luminescent bacterial reporter assay, the SOS lux test, was developed for rapid detection of environmental genotoxins. The bioassay is based on the recombinant plasmid pPLS-1, which was constructed as a derivative of pBR322, carrying the promoterless luxCDABFE genes of Photobacterium leiognathi downstream of a truncated cda gene from ColD with a strong SOS promoter. E. ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 12  شماره 

صفحات  -

تاریخ انتشار 2012