Evaluation of new online automated embolic signal detection algorithm, including comparison with panel of international experts.

نویسندگان

  • M Cullinane
  • G Reid
  • R Dittrich
  • Z Kaposzta
  • R Ackerstaff
  • V Babikian
  • D W Droste
  • D Grossett
  • M Siebler
  • L Valton
  • H S Markus
چکیده

BACKGROUND AND PURPOSE The clinical application of Doppler detection of circulating cerebral emboli will depend on a reliable automated system of embolic signal detection; such a system is not currently available. Previous studies have shown that frequency filtering increases the ratio of embolic signal to background signal intensity and that the incorporation of such an approach into an offline automated detection system markedly improved performance. In this study, we evaluated an online version of the system. In a single-center study, we compared its performance with that of a human expert on data from 2 clinical situations, carotid stenosis and the period immediately after carotid endarterectomy. Because the human expert is currently the "gold standard" for embolic signal detection, we also compared the performance of the system with an international panel of human experts in a multicenter study. METHODS In the single-center evaluation, the performance of the software was tested against that of a human expert on 20 hours of data from 21 patients with carotid stenosis and 18 hours of data from 9 patients that was recorded after carotid endarterectomy. For the multicenter evaluation, a separate 2-hour data set, recorded from 5 patients after carotid endarterectomy, was analyzed by 6 different human experts using the same equipment and by the software. Agreement was assessed by determining the probability of agreement. RESULTS In the 20 hours of carotid stenosis data, there were 140 embolic signals with an intensity of > or =7 dB. With the software set at a confidence threshold of 60%, a sensitivity of 85.7% and a specificity of 88.9% for detection of embolic signals were obtained. At higher confidence thresholds, a specificity >95% could be obtained, but this was at the expense of a lower sensitivity. In the 18 hours of post-carotid endarterectomy data, there were 411 embolic signals of > or =7-dB intensity. When the same confidence threshold was used, a sensitivity of 95.4% and a specificity of 97.5% were obtained. In the multicenter evaluation, a total of 127 events were recorded as embolic signals by at least 1 center. The total number of embolic signals detected by the 6 different centers was 84, 93, 108, 92, 63, and 78. The software set at a confidence threshold of 60% detected 90 events as embolic signals. The mean probability of agreement, including all human experts and the software, was 0.83, and this was higher than that for 2 human experts and lower than that for 4 human experts. The mean values for the 6 human observers were averaged to give P=0.84, which was similar to that of the software. CONCLUSIONS By using the frequency specificity of the intensity increase occurring with embolic signals, we have developed an automated detection system with a much improved sensitivity. Its performance was equal to that of some human experts and only slightly below the mean performance of a panel of human experts

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Automatic Detection and Localization of Surface Cracks in Continuously Cast Hot Steel Slabs Using Digital Image Analysis Techniques

Quality inspection is an indispensable part of modern industrial manufacturing. Steel as a major industry requires constant surveillance and supervision through its various stages of production. Continuous casting is a critical step in the steel manufacturing process in which molten steel is solidified into a semi-finished product called slab. Once the slab is released from the casting unit, th...

متن کامل

A Robust Feedforward Active Noise Control System with a Variable Step-Size FxLMS Algorithm: Designing a New Online Secondary Path Modelling Method

Several approaches have been introduced in literature for active noise control (ANC)systems. Since Filtered-x-Least Mean Square (FxLMS) algorithm appears to be the best choice as acontroller filter. Researchers tend to improve performance of ANC systems by enhancing andmodifying this algorithm. This paper proposes a new version of FxLMS algorithm. In many ANCapplications an online secondary pat...

متن کامل

Real-time damage detection of bridges using adaptive time-frequency analysis and ANN

Although traditional signal-based structural health monitoring algorithms have been successfully employed for small structures, their application for large and complex bridges has been challenging due to non-stationary signal characteristics with a high level of noise. In this paper, a promising damage detection algorithm is proposed by incorporation of adaptive signal processing and Artificial...

متن کامل

Improved automated detection of embolic signals using a novel frequency filtering approach.

BACKGROUND AND PURPOSE Asymptomatic embolic signal detection with the use of Doppler ultrasound has a number of potential clinical applications. However, its more widespread clinical use is severely limited by the lack of a reliable automated detection system. Design of such a system depends on accurate characterization of the unique features of embolic signals, which allow their differentiatio...

متن کامل

A New Algorithm for Voice Activity Detection Based on Wavelet Packets (RESEARCH NOTE)

Speech constitutes much of the communicated information; most other perceived audio signals do not carry nearly as much information. Indeed, much of the non-speech signals maybe classified as ‘noise’ in human communication. The process of separating conversational speech and noise is termed voice activity detection (VAD). This paper describes a new approach to VAD which is based on the Wavelet ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Stroke

دوره 31 6  شماره 

صفحات  -

تاریخ انتشار 2000