Reduced Fluorescence versus Forward Scatter Time-of-Flight and Increased Peak versus Integral Fluorescence Ratios Indicate Receptor Clustering in Flow Cytometry.

نویسندگان

  • Barbara G Fürnrohr
  • Merle Stein
  • Benjamin Rhodes
  • Prabhjoat S Chana
  • Georg Schett
  • Timothy J Vyse
  • Martin Herrmann
  • Dirk Mielenz
چکیده

Clustering of surface receptors is often required to initiate signal transduction, receptor internalization, and cellular activation. To study the kinetics of clustering, we developed an economic high-throughput method using flow cytometry. The quantification of receptor clustering by flow cytometry is based on the following two observations: first, the fluorescence signal length (FL time-of-flight [ToF]) decreases relative to the forward scatter signal length (FSc-ToF), and second, the peak FL (FL-peak) increases relative to the integral FL (FL-integral) upon clustering of FL-labeled surface receptors. Receptor macroclustering can therefore be quantified using the ratios FL-ToF/FSc-ToF (method ToF) or FL-peak/FL-integral (method Peak). We have used these methods to analyze clustering of two immune receptors known to undergo different conformational and oligomeric states: the BCR and the complement receptor 3 (CR3), on murine splenocytes, purified B cells, and human neutrophils. Engagement of both the BCR and CR3, on immortalized as well as primary murine B cells and human neutrophil, respectively, resulted in decreased FL-ToF/FSc-ToF and increased FL-peak/FL-integral ratios. Manipulation of the actin-myosin cytoskeleton altered BCR clustering which could be measured using the established parameters. To confirm clustering of CR3 on neutrophils, we applied imaging flow cytometry. Because receptor engagement is as a biological process dependent on cell viability, energy metabolism, and temperature, receptor clustering can only be quantified by gating on viable cells under physiological conditions. In summary, with this novel method, receptor clustering on nonadherent cells can easily be monitored by high-throughput conventional flow cytometry.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Polarization of scatter and fluorescence signals in flow cytometry.

BACKGROUND The pulses of light scatter and fluorescence measured in flow cytometers exhibit varying degrees of polarization. Flow cytometers are heterogeneously sensitive to this polarization, depending on the light source(s), the optical layout, and the types of mirrors and filters used. Therefore, fluorescence polarization can affect apparent intensity ratios between particles and interfere w...

متن کامل

بررسی مورفولوژی و ایمونوفنوتیپ سلولهای بنیادی مزانشیمی بعد از تعویض سرم گاوی محیط کشت به سرم انسانی

Background: Mesenchymal Stem Cells (MSCs) are used for cell therapy purposes. Fetal Bovine Serum (FBS) in culture media is essential for growth. As FBS may induce an immunological reaction and transfer pathogenic agents to MSC recipients, this study was designed to evaluate Adipose Tissue Stem Cells (ASCs) in FBS, human serum, switching of FBS to human serum and vice versa by cytology and flow ...

متن کامل

Monitoring human neutrophil granule secretion by flow cytometry: secretion and membrane potential changes assessed by light scatter and a fluorescent probe of membrane potential.

Purified human peripheral blood polymorphonuclear neutrophils (PMN) were incubated at 37 degrees C with the fluorescent membrane potential sensitive cyanine dye di-O-C(5)(3) and exposed to a number of stimulatory agents (N-formylmethionylleucylphenylalanine (FMLP), cytochalasin B (cyto B) + FMLP, phorbol myristate acetate (PMA). Flow cytometry was utilized to measure changes in forward light sc...

متن کامل

Complement-mediated lysis of pigeon erythrocyte ghosts analysed by flow cytometry. Evidence for the involvement of a 'threshold' phenomenon.

Flow-cytometric analysis of complement-mediated lysis of antibody-coated pigeon erythrocyte ghosts containing fluorescein was carried out to determine whether lysis involved a gradual release of fluorescein or a 'threshold' release from individual cells. Antibody-coated ghosts were comprised of three subpopulations identified by fluorescence and scatter (size). These were: (a) highly fluorescen...

متن کامل

A flow cytometric method to measure shape change of human neutrophils.

1. We report a flow cytometric method in which changes in forward angle light scatter are shown to correlate with microscopically evaluated shape change in stimulated human neutrophils. Neutrophil movement and chemotaxis is conventionally measured using Boyden chambers, which is a laborious and exacting technique. Microscopic scoring of neutrophil shape change has been shown to correlate well w...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of immunology

دوره 195 1  شماره 

صفحات  -

تاریخ انتشار 2015