AIMS To determine diagnostic accuracy, effective radiation dose, and potential value of computed tomography coronary angiography (CTCA) for hybrid imaging with single-photon emission computed tomography (SPECT) comparing prospective electrocardiogram (ECG)-triggering vs. retrospective ECG-gating. METHODS AND RESULTS Two hundred patients underwent standard myocardial stress/rest- SPECT perfusion imaging, which served as standard of reference. One hundred consecutive patients underwent 64-slice CTCA using prospective ECG-gating, and were compared with 100 patients who had previously undergone CTCA using retrospective ECG-gating. For predicting ischaemia, CTCA with prospective ECG-triggering and a stenosis cut-off >50% had a per-vessel sensitivity, specificity, negative, and positive predictive value of 100, 84, 100, and 30%; respective values for CTCA with retrospective ECG-gating were similar (P = n.s.): 86, 83, 98, and 33%. Combining CTCA with stress-only SPECT revealed 100% clinical agreement with regard to perfusion defects, and provided additional information in half the patients on preclinical coronary findings. Effective radiation dose was 2.2 +/- 0.7 mSv for CTCA with prospective ECG-triggering, and 19.7 +/- 4.2 mSv with retrospective ECG-gating (P < 0.001) (5.4 +/- 0.8 vs. 24.1 +/- 4.3 mSv for hybrid imaging). CONCLUSION Prospective ECG-triggering for CTCA reduces radiation dose by almost 90% without affecting diagnostic performance. Combined imaging with stress-only SPECT is an attractive alternative to standard stress/rest-SPECT for evaluation of coronary artery disease, offering additional information on preclinical atherosclerosis.
منابع مشابه
Low kilovolt “prospective ECG-triggering” vs. “retrospective ECG-gating” coronary CTA: comparison of image quality and radiation dose
Background: To compare image quality and radiation doses of low kilovolt (kV) “prospective ECG-triggering” (PT) and standard “retrospective ECG-gating” (RG) coronary computed tomography (CT) angiography. Materials and Methods: A total of 101 consecutive patients (76 males, 25 females; mean age: 55.44 ± 8.28 years) with low-to-intermediate risk status for coronary artery disease and with a body ...
متن کاملBrain Single Photon Emission Computed Tomography Scan (SPECT) and Functional MRI in Systemic Lupus Erythematosus Patients with Cognitive Dysfunction: A Systematic Review
Objective(s): Systemic lupus erythematosus (SLE) is an autoimmune disease with a wide range of clinical manifestations. Cognitive dysfunction is one of the manifestations that could present prior to the emergence of any other neuropsychiatric involvements in SLE. Cognitive dysfunction is a subtle condition occurring with ahigh frequency. However, there is no data on the correlation of cognitive...
متن کاملImprovement of diagnostic accuracy of Parkinson's disease on I-123-ioflupane single photon emission computed tomography (123I FP-CIT SPECT) using new Japanese normal database
Objective(s): I-123-ioflupane single photon emission computed tomography (FP-CIT-SPECT) has been used to assess dopamine transporter (DAT) loss in Parkinson's disease. The specific binding ratio (SBR), a quantitative parameter of DAT density in the striatum, may be affected by differences in age, sex, and SPECT system. The purpose of this study was to evaluate the util...
متن کاملApplication of 64-slice spiral computed tomography angiography in a follow-up evaluation after coronary stent implantation: A Chinese clinical study
Background: This study assessed the application value of 64-slice spiral computed tomography angiography (CTA) in a follow-up evaluation of patients receiving coronary stent implantation. Materials and Methods: A total of 468 patients who underwent percutaneous coronary intervention (PCI) at our hospital between January 2013 and October 2016 were selected for this study. Coronary angiography an...
متن کاملPrediction of Changes in Left Ventricular Ejection Fraction after Off-Pump Coronary Artery Bypass Grafting Surgery by Myocardial Perfusion Single-Photon Emission Computed Tomography
Introduction: Left ventricular ejection fraction (LVEF) is considered to be the single most important prognostic factor in patients with previous myocardial infarction. LVEF is not improved in all patients after coronary artery bypass grafting (CABG). This study aimed to assess the possibility of prediction of LVEF changes after CABG using myocardial perfusion gated signle photon emission compu...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- European heart journal
دوره 30 5 شماره
صفحات -
تاریخ انتشار 2009