Preliminary 3-dimensional surface texture measurement and early loading results with a microtextured implant surface.
نویسندگان
چکیده
PURPOSE This investigation was conducted to obtain preliminary roughness data on a microtextured implant surface and to determine its ability to sustain a 1-stage surgical procedure and early full occlusal loading of single-tooth restorations in humans. MATERIALS AND METHODS Three-dimensional (3D) vertical scanning interferometry was conducted on samples of the test surface (MTX) and 2 control surfaces (Osseotite and sandblasted/acid-etched [SLA]). Test implants were also placed in vivo, restored with fully occluding single-tooth restorations (n = 27) after 2 months of nonsubmerged healing, and clinically monitored for 48 months of follow-up. RESULTS Microtexture was relatively uniform on the test surface and more random and irregular on the control surfaces. MTX and Osseotite were similar in some roughness parameters, but the MTX surface had a greater number of micropits that were spaced closer together (Stylus Y lambda q) and with higher slope values (Stylus Y delta q). Cumulative life table results were 100% for all MTX implants placed in maxillary and mandibular jaw locations, and no discernible marginal bone changes were observed. Overall implant success was 100% after 4 years of clinical functioning. DISCUSSION The findings of this study appear promising but should be considered preliminary, because of the limitations in the number of locations measured on each product sample and the small number of implants clinically studied. CONCLUSION Within the scope of the present study, MTX implants exhibited a uniform micropitted surface, as well as 100% survival and 100% clinical success after nonsubmerged placement, early loading with single-tooth restorations at 2 months, and 48 months of clinical functioning. (More than 50 references.)
منابع مشابه
Histomorphometric evaluation of six dental implant surfaces after early loading in augmented human sinuses.
This study investigated the bone-to-implant contact (BIC) and osteoconductive capacity (OC) of 6 different implant surfaces after early loading in humans. Two implants with different surfaces were placed side-by-side in the grafted (n= 5) and nongrafted (n = 1) sinuses of 3 volunteers. Single-tooth restorations were delivered 60 days later. After 6 months of full occlusal loading, implants were...
متن کاملImmediate loading in dental implants ( A literature review )
Immediate loading in dental implants ( A literature review ) Dr. Seyedan K.,1 Dr. Hafezeqoran A.,2 Dr. Sazgara H.3 1Assistant Professor, Department of Prosthodentists,Dental School Shahid Beheshti University of Medical Sciences,Tehran, Iran.2Dentist, Post Graduate Student, Department of Prosthodontics, Dental School, Shahid Beheshti University of Medical Sciences, Tehran-Iran.3Associate Profess...
متن کاملRadiographic Comparison of Crestal Bone Loss Around Two Implant Systems with Different Surface Roughness: A Retrospective Study
Background and Aim: This retrospective study aimed to investigate the effects of surface roughness and implant body design on the amount of crestal bone loss around implant. Materials and Methods: In this retrospective study, dental records of 87 patients who received 139 implants were evaluated. The ITI group received 63 implants with moderate roughness, while the DIO group received 76 implan...
متن کاملThe effect of a subcutaneous silicone rubber implant with shallow surface microgrooves on the surrounding tissues in rabbits.
It has been suggested that during wound healing microtextured surfaces can alter events at the interface between implant surface surface and surrounding tissues. To investigate this phenomenon, smooth and microtextured silicone rubber implants were implanted subcutaneously in rabbits for 3, 7, 42, and 84 days. The textured implants possessed parallel surface microgrooves and ridges with a width...
متن کاملHuman Mesenchymal Stem Cell Morphology and Migration on Microtextured Titanium
The implant used in spinal fusion procedures is an essential component to achieving successful arthrodesis. At the cellular level, the implant impacts healing and fusion through a series of steps: first, mesenchymal stem cells (MSCs) need to adhere and proliferate to cover the implant; second, the MSCs must differentiate into osteoblasts; third, the osteoid matrix produced by the osteoblasts ne...