Reproducibility studies and interlaboratory concordance for androgen assays in female plasma.
نویسندگان
چکیده
We conducted studies to determine the magnitude and sources of variability in androgen assay results and to identify laboratories capable of performing such assays for large epidemiological studies. We studied androstanediol (ADIOL), androstanediol glucuronide (ADIOL G), androstenedione (ADION), androsterone glucuronide (ANDRO G), androsterone sulfate (ANDRO S), dehydroepiandrosterone (DHEA), dehydroepiandrosterone sulfate (DHEA S), dihydrotestosterone (DHT), and testosterone (TESTO). A single sample of plasma was obtained from five postmenopausal women, five premenopausal women in the midfollicular phase of the menstrual cycle, and five women in the midluteal phase, divided into aliquots, and stored at -70 degrees. Four sets of two coded aliquots from each woman were then sent to participating labs for analysis at monthly intervals over 4 months. Using the logarithm of assay measurements, we estimated the components of variance and three measures of reproducibility. The usual coefficient of variation is a function of the components that are under the control of the laboratory. The intraclass correlation between measurements for a given individual is the proportion of the total variability that is associated with individuals. The minimum detectable relative difference is important to evaluate study feasibility. Results suggest that a single sample of ADIOL G, DHEA, DHEA S, and ANDRO G (with two lab replicates per sample) can be used to discriminate reliably among women in a given menstrual phase or menopausal status. The results for DHT, TESTO, ADION, and ANDRO S are more problematic and suggest that the present measurement techniques should be used with care, especially with midluteal phase women. The results for ADIOL suggest that this assay is not yet ready for use in epidemiological studies.
منابع مشابه
Reproducibility studies and interlaboratory concordance for androgen assays of male plasma hormone levels.
To help us identify appropriate techniques and laboratories for measuring hormones, we studied the variability and reproducibility of assay measurements of androstanediol glucuronide, androstenedione, dehydroepiandrosterone (DHEA), DHEA sulfate, dihydrotestosterone, testosterone, androstanediol, androsterone glucuronide, and androsterone sulfate for five men. Four sets of two aliquots from each...
متن کاملResolving the ductal carcinoma in situ treatment conundrum.
680 Editorials | JNCI 14. Gail MH, Fears TR, Hoover RN, et al. Reproducibility studies and interlaboratory concordance for assays of serum hormone levels: estrone, estradiol, estrone sulfate, and progesterone. Cancer Epidemiol Biomarkers Prev. 1996;5(10):835–844. 15. Houseman EA, Accomando WP, Koestler DC, et al. DNA methylation arrays as surrogate measures of cell mixture distribution. BMC Bio...
متن کاملKey Lessons from Performance of the U.S. EPA Endocrine Disruptor Screening Program (EDSP) Tier 1 Male and Female Pubertal Assays
The male and female pubertal assays, which are included in the U.S. Environmental Protection Agency's (EPA) Endocrine Disruptor Screening Program (EDSP) Tier 1 battery, can detect endocrine-active compounds operating by various modes of action. This article uses the collective experience of three laboratories to provide information on pubertal assay conduct, interlaboratory reproducibility, end...
متن کاملResults of an interlaboratory method performance study for the size determination and quantification of silver nanoparticles in chicken meat by single-particle inductively coupled plasma mass spectrometry (sp-ICP-MS)
Single-particle inductively coupled plasma mass spectrometry (sp-ICP-MS) promises fast and selective determination of nanoparticle size and number concentrations. While several studies on practical applications have been published, data on formal, especially interlaboratory validation of sp-ICP-MS, is sparse. An international interlaboratory study was organized to determine repeatability and re...
متن کاملEnhancing reproducibility in cancer drug screening: how do we move forward?
Large-scale pharmacogenomic high-throughput screening (HTS) studies hold great potential for generating robust genomic predictors of drug response. Two recent large-scale HTS studies have reported results of such screens, revealing several known and novel drug sensitivities and biomarkers. Subsequent evaluation, however, found only moderate interlaboratory concordance in the drug response pheno...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Cancer epidemiology, biomarkers & prevention : a publication of the American Association for Cancer Research, cosponsored by the American Society of Preventive Oncology
دوره 9 4 شماره
صفحات -
تاریخ انتشار 2000