Hemodynamic and exercise performance with pulsatile and continuous-flow left ventricular assist devices.

نویسندگان

  • Jonathan Haft
  • William Armstrong
  • David B Dyke
  • Keith D Aaronson
  • Todd M Koelling
  • David J Farrar
  • Francis D Pagani
چکیده

BACKGROUND Continuous-flow rotary pumps with axial design are increasingly used for left ventricular assist support. The efficacy of this design compared with pulsatile, volume displacement pumps, with respect to characteristics of left ventricular unloading, and exercise performance remains largely unstudied. METHODS AND RESULTS Thirty-four patients undergoing implantation with a pulsatile, volume displacement pump operating in a full-to-empty cycle (HeartMate XVE; Thoratec Inc, Pleasanton, Calif; n=16) or continuous-flow rotary pump with an axial design operating at a fixed rotor speed (HeartMate II; Thoratec Inc; n=18) were evaluated with right heart catheterization and echocardiography preoperatively and at 3 months postoperatively and cardiopulmonary exercise testing 3 months postoperatively. Support with either the XVE or II resulted in significant (P<0.05) increases in cardiac output and reduction in mean pulmonary artery and pulmonary wedge pressures. Exercise capacity at 3 months was similar between groups (% predicted peak VO2-XVE: 46.8+/-10.2 versus II: 49.1+/-13.6). Echocardiography at 3 months demonstrated a significantly (P<0.05) greater reduction in left ventricular end-diastolic volume (-49+/-16% versus -35+/-20%), left ventricular end-systolic volume (-59+/-20 versus -37+/-21%), and percent mitral valve regurgitant volume (-99+/-2% versus -52+/-56%) for the XVE compared with II, respectively. CONCLUSIONS The HeartMate XVE or II provided equivalent degrees of hemodynamic support and exercise capacity. The XVE was associated with greater left ventricular volume unloading. Characteristics of left ventricular pressure and volume unloading between these pump designs and mode of operation do not influence early exercise performance.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Factors influencing the rate of flow through continuous-flow left ventricular assist devices at rest and with exercise.

T he heart failure (HF) community has witnessed a rapid evolution in mechanical circulatory support over the past decade. Following publication of the pivotal HeartMate II trials, continuous-flow left ventricular assist devices (cfLVADs) with an axial rotor (e.g., HeartMate II) quickly replaced the first-generation, pulsatile devices as both a bridge to transplant and as destination therapy for...

متن کامل

A Mock Circulatory System to Assess the Performance of Continuous-Flow Left Ventricular Assist Devices (LVADs): Does Axial Flow Unload Better Than Centrifugal LVAD?

Hemodynamic performances comparisons between different types of left ventricular assist devices (LVADs) remain difficult in a clinical context. The aim of this study was to create an experimental model to assess and compare two types of LVAD under hemodynamic conditions that simulated physical effort and pulmonary hypertension. An experimental mock circulatory system was created to simulate the...

متن کامل

Sympathetic neural and hemodynamic responses to upright tilt in patients with pulsatile and nonpulsatile left ventricular assist devices.

BACKGROUND Left ventricular assist devices (LVADs) are now widely accepted as an option for patients with advanced heart failure. First-generation devices were pulsatile, but they had poor longevity and durability. Newer generation devices are nonpulsatile and more durable, but remain associated with an increased risk of stroke and hypertension. Moreover, little is understood about the physiolo...

متن کامل

Left ventricular assist devices decrease fixed pulmonary hypertension in cardiac transplant candidates.

OBJECTIVE Fixed pulmonary hypertension is a contraindication for cardiac transplantation because of the increased risk of donor heart failure. We sought to determine whether left ventricular assist devices improve fixed pulmonary hypertension in cardiac transplant candidates to enable safe cardiac transplantation. METHODS Thirty-five consecutive cardiac transplant candidates (age 56 +/- 6 yea...

متن کامل

Novel strategy to improve end-organ function with pulsatile cardiopulmonary bypass.

he advent of cardiopulmonary bypass (CPB) has enabled cardiovascular surgeons to perform complex, life-saving procedures with relative ease while protecting end-organ function. Altering the normal pulsatile blood flow to non-pulsatile continuous flow has raised concerns over potential detrimental hemodynamic and physiologic consequences. Concerns over long-term non-pulsatile flow drove the desi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation

دوره 116 11 Suppl  شماره 

صفحات  -

تاریخ انتشار 2007