Routine versus on demand removal of the syndesmotic screw; a protocol for an international randomised controlled trial (RODEO-trial)

نویسندگان

  • S. A. Dingemans
  • M. F. N. Birnie
  • F. R. K. Sanders
  • M. P. J. van den Bekerom
  • M. Backes
  • E. van Beeck
  • F. W. Bloemers
  • B. van Dijkman
  • E. Flikweert
  • D. Haverkamp
  • H. R. Holtslag
  • J. M. Hoogendoorn
  • P. Joosse
  • M. Parkkinen
  • G. Roukema
  • N. Sosef
  • B. A. Twigt
  • R. N. van Veen
  • A. H. van der Veen
  • J. Vermeulen
  • J. Winkelhagen
  • B. C. van der Zwaard
  • S. van Dieren
  • J. C. Goslings
  • T. Schepers
چکیده

BACKGROUND Syndesmotic injuries are common and their incidence is rising. In case of surgical fixation of the syndesmosis a metal syndesmotic screw is used most often. It is however unclear whether this screw needs to be removed routinely after the syndesmosis has healed. Traditionally the screw is removed after six to 12 weeks as it is thought to hamper ankle functional and to be a source of pain. Some studies however suggest this is only the case in a minority of patients. We therefore aim to investigate the effect of retaining the syndesmotic screw on functional outcome. DESIGN This is a pragmatic international multicentre randomised controlled trial in patients with an acute syndesmotic injury for which a metallic syndesmotic screw was placed. Patients will be randomised to either routine removal of the syndesmotic screw or removal on demand. Primary outcome is functional recovery at 12 months measured with the Olerud-Molander Score. Secondary outcomes are quality of life, pain and costs. In total 194 patients will be needed to demonstrate non-inferiority between the two interventions at 80% power and a significance level of 0.025 including 15% loss to follow-up. DISCUSSION If removal on demand of the syndesmotic screw is non-inferior to routine removal in terms of functional outcome, this will offer a strong argument to adopt this as standard practice of care. This means that patients will not have to undergo a secondary procedure, leading to less complications and subsequent lower costs. TRIAL REGISTRATION This study was registered at the Netherlands Trial Register (NTR5965), Clinicaltrials.gov ( NCT02896998 ) on July 15th 2016.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Complications of syndesmotic screw removal.

BACKGROUND Currently, the metallic syndesmotic screw is the gold standard in the treatment of syndesmotic disruption. Whether or not this screw needs to be removed remains debatable. The aim of the current study was to determine the complications which occur following routine removal of the syndesmotic screw following operative treatment of unstable ankle fractures. METHODS This was a retrosp...

متن کامل

Flexible Multi-dose GnRH Antagonist versus Long GnRH Agonist Protocol in Poor Responders: A Randomized Controlled Trial

Background To compare a flexible, multi-dose GnRH antagonist protocol with a long GnRH .agonist protocol in poor respo MaterialsAndMethods A randomized clinical trial of 70 poor responder patients (35 patients in GnRH antagonist protocol and 35 patients in long GnRH agonist protocol) was performed at Royan Institute, Tehran, Iran. Both groups were given a fixed dose of human menopausal gonadotr...

متن کامل

O-30: Novel Interventions to Reduce ReInfection in Women with Chlamydia: A Randomised-Controlled Trial

Background: To determine if postal testing kits (PTK) and patient delivered partner therapy (PDPT) for managing sexual partners of women with Chlamydia tracho-matis, reduce re-infection rates in women, compared to partner notification by patient referral. Materials and Methods: Three hundred and thirty women testing positive for chlamydia, at clinics for genitourinary medicine, family planning ...

متن کامل

P-78: A Randomised Placebo-Controlled Trial to Determine the Effect of Iron Supplementation on Neonatal Outcome in Pregnant Women with Normal Heamoglobin (Hb=11-13

Background: To study the effect of iran supplementation on neonal outcom in pregnant women with normal heamoglobin (Hb=11g/dl )13 g/dl Methods : two handrad pregnant women with Hb=11-13 g/dl in the early slage of pregmancy? Materials and Methods: Each woman look one tablet of 50 mg of ferrossalphate daily in the case group (n=100) and placebo group (n=100). Results: While no significant differe...

متن کامل

A prospective randomised study comparing TightRope and syndesmotic screw fixation for accuracy and maintenance of syndesmotic reduction assessed with bilateral computed tomography.

BACKGROUND The accuracy and maintenance of syndesmosis reduction are essential when treating ankle fractures with accompanying syndesmosis injuries. The primary aim of this study was to compare syndesmosis screw and TightRope fixation in terms of accuracy and maintenance of syndesmosis reduction using bilateral computed tomography (CT). STUDY DESIGN Single centre, prospective randomised contr...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 19  شماره 

صفحات  -

تاریخ انتشار 2018