Dark blood late enhancement imaging

نویسندگان

  • Peter Kellman
  • Hui Xue
  • Laura J Olivieri
  • Russell R Cross
  • Elena K Grant
  • Marianna Fontana
  • Martin Ugander
  • James C Moon
  • Michael S Hansen
چکیده

BACKGROUND Bright blood late gadolinium enhancement (LGE) imaging typically achieves excellent contrast between infarcted and normal myocardium. However, the contrast between the myocardial infarction (MI) and the blood pool is frequently suboptimal. A large fraction of infarctions caused by coronary artery disease are sub-endocardial and thus adjacent to the blood pool. It is not infrequent that sub-endocardial MIs are difficult to detect or clearly delineate. METHODS In this present work, an inversion recovery (IR) T2 preparation was combined with single shot steady state free precession imaging and respiratory motion corrected averaging to achieve dark blood LGE images with good signal to noise ratio while maintaining the desired spatial and temporal resolution. In this manner, imaging was conducted free-breathing, which has benefits for image quality, patient comfort, and clinical workflow in both adults and children. Furthermore, by using a phase sensitive inversion recovery reconstruction the blood signal may be made darker than the myocardium (i.e., negative signal values) thereby providing contrast between the blood and both the MI and remote myocardium. In the proposed approach, a single T1-map scout was used to measure the myocardial and blood T1 using a MOdified Look-Locker Inversion recovery (MOLLI) protocol and all protocol parameters were automatically calculated from these values within the sequence thereby simplifying the user interface. RESULTS The contrast to noise ratio (CNR) between MI and remote myocardium was measured in n = 30 subjects with subendocardial MI using both bright blood and dark blood protocols. The CNR for the dark blood protocol had a 13 % loss compared to the bright blood protocol. The CNR between the MI and blood pool was positive for all dark blood cases, and was negative in 63 % of the bright blood cases. The conspicuity of subendocardial fibrosis and MI was greatly improved by dark blood (DB) PSIR as well as the delineation of the subendocardial border. CONCLUSIONS Free-breathing, dark blood PSIR LGE imaging was demonstrated to improve the visualization of subendocardial MI and fibrosis in cases with low contrast with adjacent blood pool. The proposed method also improves visualization of thin walled fibrous structures such as atrial walls and valves, as well as papillary muscles.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Dark blood Late Gadolinium Enhancement improves conspicuity of ablation lesions

Background Cardiac MR has begun to be utilized for imaging ablation lesions. Peri-procedural imaging could potentially be used to guide therapy, but this application has unique requirements and limitations. In peri-procedural imaging of acute lesions, subjects are frequently sedated and imaging should be conducted free-breathing. Furthermore, Late Gadolinium Enhancement (LGE) imaging of sub-end...

متن کامل

Bright-blood T2-weighted MRI has higher diagnostic accuracy than dark-blood short tau inversion recovery MRI for detection of acute myocardial infarction and for assessment of the ischemic area at risk and myocardial salvage.

BACKGROUND T2-Weighted MRI reveals myocardial edema and enables estimation of the ischemic area at risk and myocardial salvage in patients with acute myocardial infarction (MI). We compared the diagnostic accuracy of a new bright-blood T2-weighted with a standard black blood T2-weighted MRI in patients with acute MI. METHODS AND RESULTS A breath-hold, bright-blood T2-weighted, Acquisition for...

متن کامل

Prospective comparison of novel dark blood late gadolinium enhancement with conventional bright blood imaging for the detection of scar

BACKGROUND Conventional bright blood late gadolinium enhancement (bright blood LGE) imaging is a routine cardiovascular magnetic resonance (CMR) technique offering excellent contrast between areas of LGE and normal myocardium. However, contrast between LGE and blood is frequently poor. Dark blood LGE (DB LGE) employs an inversion recovery T2 preparation to suppress the blood pool, thereby incre...

متن کامل

Dark-blood late gadolinium enhancement without additional magnetization preparation

BACKGROUND This study evaluates a novel dark-blood late gadolinium enhancement (LGE) cardiovascular magnetic resonance imaging (CMR) method, without using additional magnetization preparation, and compares it to conventional bright-blood LGE, for the detection of ischaemic myocardial scar. LGE is able to clearly depict myocardial infarction and macroscopic scarring from viable myocardium. Howev...

متن کامل

Accuracy of a prototype dark blood late gadolinium enhancement technique for the detection and quantification of myocardial infarction

Background Conventional inversion recovery (IR) techniques for the detection of late gadolinium enhancement (LGE) in the myocardium are bright blood methods in which the signal in the blood chamber is often similar to the signal in hyperenhanced irreversibly damaged myocardial areas. Due to the low contrast to noise ratio (CNR) between blood and the hyperenhanced myocardium at the tissue-blood ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 18  شماره 

صفحات  -

تاریخ انتشار 2016