Proof-of-concept demonstration of edge-illumination x-ray phase contrast imaging combined with tomosynthesis.
نویسندگان
چکیده
In this note we present the first proof-of-concept results on the potential effectiveness of the edge-illumination x-ray phase contrast method (in its 'coded-aperture' based lab implementation) combined with tomosynthesis. We believe that, albeit admittedly preliminary (e.g. we only present phantom work), these results deserve early publication in a note primarily for four reasons. First, we fully modelled the imaging acquisition method, and validated the simulation directly with experimental results. This shows that the implementation of the method in the new geometry is understood, and thus that it will be possible to use the model to simulate more complex scenarios in the future. Secondly, we show that a strong phase contrast signal is preserved in the reconstructed tomosynthesis slices: this was a concern, as the high spatial frequency nature of the signal makes it sensitive to any filtration-related procedure. Third, we show that, despite the non-optimized nature of the imaging prototype used, we can perform a full angular scan at acceptable dose levels and with exposure times not excessively distant from what is required by clinical practice. Finally, we discuss how the proposed phase contrast method, unlike other approaches apart from free-space propagation (which however requires a smaller focal spot, thus reducing the flux and increasing exposure times), can be easily implemented in a tomosynthesis geometry suitable for clinical use. In summary, we find that these technical results indicate a high potential for the combination of the two methods. Combining slice separation with detail enhancement provided by phase effects would substantially increase the detectability of small lesions and/or calcifications, which we aim to demonstrate in the next steps of this study.
منابع مشابه
Small angle x-ray scattering with edge-illumination
Sensitivity to sub-pixel sample features has been demonstrated as a valuable capability of phase contrast x-ray imaging. Here, we report on a method to obtain angular-resolved small angle x-ray scattering distributions with edge-illumination- based imaging utilizing incoherent illumination from an x-ray tube. Our approach provides both the three established image modalities (absorption, differe...
متن کاملThe effect of the spatial sampling rate on quantitative phase information extracted from planar and tomographic edge illumination x-ray phase contrast images
The effect of the spatial sampling rate on the quantitative phase information that can be retrieved from planar and tomographic edge illumination (EI) x-ray phase contrast imaging (XPCi) with a laboratory-based prototype scanner is analysed. The study is conducted on simulated and experimental data from a custom-built phantom. Optimal sampling rates, i.e. the minimum ones allowing the unambiguo...
متن کاملAsymmetric masks for laboratory-based X-ray phase-contrast imaging with edge illumination
We report on an asymmetric mask concept that enables X-ray phase-contrast imaging without requiring any movement in the system during data acquisition. The method is compatible with laboratory equipment, namely a commercial detector and a rotating anode tube. The only motion required is that of the object under investigation which is scanned through the imaging system. Two proof-of-principle op...
متن کاملNote: Design and realization of a portable edge illumination X-ray phase contrast imaging system.
We discuss a portable edge illumination x-ray phase contrast imaging system based on compact piezoelectric motors, which enables its transportation to different environments, e.g., hosting different x-ray source technologies. The analysis of images of standard samples reveals an angular sensitivity of 270 ± 6 nrad, which compares well with the 260 ± 10 nrad reported for previous systems based o...
متن کاملRecent advances in edge illumination x-ray phase-contrast tomography.
Edge illumination (EI) is an x-ray phase-contrast imaging technique, exploiting sensitivity to x-ray refraction to visualize features, which are often not detected by conventional absorption-based radiography. The method does not require a high degree of spatial coherence and is achromatic and, therefore, can be implemented with both synchrotron radiation and commercial x-ray tubes. Using diffe...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Physics in medicine and biology
دوره 59 5 شماره
صفحات -
تاریخ انتشار 2014