Characterization of Fluor Concentration and Geometry in Organic Scintillators for in Situ Beta Imagi - Nuclear Science, IEEE Transactions on
نویسندگان
چکیده
Development of a small area (1–2 cm) in situ beta imaging device includes optimization of the front end scintillation detector, which is fiber optically coupled to a remote photon detector. Thin plastic scintillation detectors, which are sensitive to charged particles, are the ideal detectors due to the low sensitivity to ambient gamma backgrounds. The light output of a new binary plastic scintillator was investigated with respect to increasing concentrations of the fluor (0.5–2.0% by weight) and varying thickness cylindrical configurations of the intended imaging detector. The fluor had an emission maximum increasing from 431 to 436 nm with increasing fluor concentration. The decay time(s) had two components (0.38 and 1.74 ns). There was an 20% increase in light output with increasing fluor concentration, measured with both 204Tl betas and conversion electrons from 207Bi. The highest light output of this new scintillator was measured to be 30% lower than BC404. Simulations predicted the 1.5 mm scintillator thickness at which light output and energy absorption for 700 keV electrons (e.g., from 204Tl, F) were maximized, which corresponded with measurements. As beta continua are relatively featureless, energy calibration for the thin scintillators was investigated using Landau distributions, which appear as distinct peaks in the spectra. As the scintillators were made thinner, gamma backgrounds were shown to linearly decrease.
منابع مشابه
CHARACTERIZATION OF FLUOR CONCENTRATION AND GEOMETRY IN ORGANIC SCINTILLATORS FOR IN SITU BETA IMAGI - Nuclear Science Symposium and Medical Imaging Conference Record, 1995., 1995 IEEE
Gamma transparent materials are necessary to avoid detection Development of a small area (1-2 cm2) in situ beta imaging device includes optimization of the front end scintillation detector which is fiber optically coupled to a remote photon detector. Thin plastic scintillation detectors, which are sensitive to charged particles, are the ideal detectors due to the low sensitivity to ambient gamm...
متن کاملOPTIMIZING LIGHT COLLECTION FROM THIN SCINTILLATORS USED IN A BETA-RAY CAMERA FOR SURGICAL USE - Nuclear Science, IEEE Transactions on
We are developing a 1-2 cm2 area camera for imaging the distribution of beta-emitting radiopharmaceuticals at the surface of tissue exposed during surgery. The front end consists of a very thin continuous or segmented scintillator sensitive to betas (positrons or electrons) of a few hundred keV, yet insensitive to gamma rays. The light from the scintillator is piped through clear fibers to the ...
متن کاملExploring the potential of complex-vesicle based niosomal ocular system loaded with azithromycin: Development of in situ gel and ex vivo characterization
Abstract Bacterial conjunctivitis characterized as pink eye referred as an inflammation of an eye caused by the enlargement of blood vessels present in conjunctiva, resulting in a red or bloodshot appearance of the eyes. Topical ocular delivery is found to be useful in treating conjunctivitis, but to maintain an effective drug concentration at a site of action in order to achieve desired pha...
متن کاملSynthesis, Characterization, and Antibacterial Activity of ZnO Nanoparticles from Organic Extract of Cola Nitida and Cola Acuminata Leaf
The study aimed at the synthesis and antibacterial activity of ZnO nanoparticles (NPs) from organic extracts of Cola nitida and Cola acuminata leaf using zinc chloride (ZnCl2) and zinc acetate dihydrate [Zn(CH3COO)2∙2H2O] as precursors on selected Gram positive and Gram negative microbes: Staphylococcus aureus, Exiguobacterium aquaticu...
متن کاملOne-step Cathodic Electrochemical Synthesis and Characterization of Dextran Coated Magnetite Nanoparticles
In this research, a simple and efficient cathodic electrochemical deposition (CED) route wasdeveloped for the preparation of magnetite nanoparticles (NPs) in an aqueous media. Thesurface of magnetite NPs was also coated for the first time via an in situ procedure during theCED process. In this method, initially, the Fe3O4 NPs (with size ~10 nm) were prepared from theFe2+/Fe3+ chloride bath thro...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 1998