SU-E-J-46: Use of Brainlab-ExacTrac IGRT with Dot-Decimal Electron Compensator(BolusECT) for Accurate Patient Positioning.

نویسندگان

  • A Prabhu
  • D Saini
  • B Patadiya
  • R Shankar
  • T Garthwaite
چکیده

PURPOSE To Validate Brainlab-ExacTrac IGRT with Dot-Decimal electron compensator(BolusECT) for accurate patient positioning. METHODS Dot-Decimal electron compensators(BolusECT) are used to achieve conformal dose distributions and greater sparing to normal structures for cases with varying patient contours and treated with single electron beam.Setup for such patients is difficult to verify due to the small clearance between theelectron-cone and bolus. Hence additional verification is needed for fast setup to avoid discomfort for the patient. In this study we have explored theuse of Brainlab-ExacTrac IGRT system for such setups.A Preplan isrequired to construct the BolusECT and a post-plan is used for verifying the treatment plan. Before the patient is scanned again with BolusECT for post-plan, tungsten BBs were drilled in the Bolus at different depths and the holeswere filled with wax. Tungsten-BBs have high density and avoid high cost ofgold seeds.A wax phantom and BolusECT were scanned with BBs and a plan was generated. The plan was send to ExacTrac for DRR-generation.The Wax phantom with BolusECT was then set slightly off centered on thetreatment couch and the ExactTrac system was used to align the Phantom. The ExacTrac system was also tried on two patients for accurate setup. RESULTS The ExactTrac system correctly identified the tungsten-BBs and aligned the phantom within +1mm. The SSD was then verified and checked with the planned SSD.The SSD was found to be within +0.5mm. In both patient setups the ExacTrac system gave Lateral, Longitudinal and Vertical Shifts within +1mm and the SSD was found to be within +0.3mm of the planned SSD. CONCLUSIONS The BrainLab- ExacTrac IGRT system isan excellent,fast way of aligning the BolusECT. This avoids discomfort for patients by preventing longer setup times. Use of tungsten-BBs lowers the cost compared to gold seeds. Phantom verification should be performed before implementing this system for actual patient use. The SSDs must be verified after setup.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

SU-E-J-69: Development of an Ambiguity-Free Optical Tracking System for SBRT.

PURPOSE Commercial optical tracking system such as BrainLab ExacTrac© suffers from ambiguous markers which can cause significant delay in patient treatment. We developed an ambiguity-free optical tracking system for high precision SBRT. METHODS The optical tracking system consists of a pair of camera sensors, 4∼8 infra-red (IR) reflective markers affixed on patient skin and in-house developed...

متن کامل

A novel compound 6D‐offset simulating phantom and quality assurance program for stereotactic image‐guided radiation therapy system

A comprehensive quality assurance (QA) device cum program was developed for the commissioning and routine testing of the 6D IGRT systems. In this article, both the new QA system and the BrainLAB IGRT system which was added onto a Varian Clinac were evaluated. A novel compound 6D-offset simulating phantom was designed and fabricated in the Prince of Wales Hospital (PWH), Hong Kong. The QA progra...

متن کامل

Local control and overall survival after frameless radiosurgery: A single center experience

Introduction Stereotactic radiosurgery (SRS) has been increasingly advocated for 1-3 small brain metastases. The goal of this study was to evaluate the clinical results in patients with brain metastases treated with LINAC-based SRS using a thermoplastic mask (non-invasive fixation system) and Image-Guided Radiotherapy (IGRT). Material and Methods In this single-institution study 48 patients w...

متن کامل

Quantitative evaluation of patient setup uncertainty of stereotactic radiotherapy with the frameless 6D ExacTrac system using statistical modeling

The purpose of this study is to evaluate patient setup accuracy and quantify indi-vidual and cumulative positioning uncertainties associated with different hardware and software components of the stereotactic radiotherapy (SRS/SRT) with the frameless 6D ExacTrac system. A statistical model is used to evaluate positioning uncertainties of the different components of SRS/SRT treatment with the Br...

متن کامل

Evaluation of Six-Dimensional Cranial Target Positioning Accuracy in Two Different Immobilization Methods Using Exactrac System

Introduction: The aim of this study was to determine the accuracy of two different immobilization methods in patient positioning in cranial radiotherapy. The six-dimensional (6D) target localization accuracy of using a dedicated stereotactic mask was compared with that of a conventional head mask by the ExacTrac system. Material and Methods: ...

متن کامل