Fiber-based polarization-sensitive Mueller matrix optical coherence tomography with continuous source polarization modulation.
نویسندگان
چکیده
We report on a new configuration of fiber-based polarization-sensitive Mueller matrix optical coherence tomography that permits the acquisition of the round-trip Jones matrix of a biological sample using only one light source and a single depth scan. In this new configuration, a polarization modulator is used in the source arm to continuously modulate the incident polarization state for both the reference and the sample arms. The Jones matrix of the sample can be calculated from the two frequency terms in the two detection channels. The first term is modulated by the carrier frequency, which is determined by the longitudinal scanning mechanism, whereas the other term is modulated by the beat frequency between the carrier frequency and the second harmonic of the modulation frequency of the polarization modulator. One important feature of this system is that, for the first time to our knowledge, the Jones matrix of the sample can be calculated with a single detection channel and a single measurement when diattenuation is negligible. The system was successfully tested by imaging both standard polarization elements and biological samples.
منابع مشابه
Time-domain Polarization-sensitive Optical Coherence Tomography in Soft Biological Tissue
Time-Domain Polarization-Sensitive Optical Coherence Tomography in Soft Biological Tissue. (August 2008) Milos Todorovic, B.S., University of Belgrade; M.S., Texas A&M University Co-Chairs of Advisory Committee, Dr. Lihong V. Wang Dr. Gerard L. Cote A new, high-speed, fiber-based Mueller-matrix optical coherence tomography system with continuous source-polarization modulation is presented. For ...
متن کاملPreliminary Study on Skin Cancer Detection in Sencar Mice Using Mueller Optical Coherence Tomography
We report on the use of a fiber-based Mueller-matrix optical coherence tomography (OCT) system with continuous source-polarization modulation for in vivo imaging of early stages of skin cancer in SENCAR mice. A homemade hand-held probe with integrated optical scanning and beam delivering optics was coupled in the sample arm. The OCT images show the morphological changes in skin resulting from p...
متن کاملPolarization-sensitive optical coherence tomography using continuous polarization modulation with arbitrary phase modulation amplitude.
We demonstrate theoretically and experimentally that the phase retardance and relative optic-axis orientation of a sample can be calculated without prior knowledge of the actual value of the phase modulation amplitude when using a polarization-sensitive optical coherence tomography system based on continuous polarization modulation (CPM-PS-OCT). We also demonstrate that the sample Jones matrix ...
متن کاملComment on "Optical-fiber-based Mueller optical coherence tomography".
We comment on the recent Letter by Jiao et al. [Opt. Lett. 28, 1206 (2003)] in which a polarization-sensitive optical coherence tomography system was presented. Interrogating a sample with two orthogonal incident polarization states cannot always recover birefringence correctly. A previously presented fiber-based polarization-sensitive system was inaccurately characterized, and its method of el...
متن کاملFiber-based polarization-sensitive Fourier domain optical coherence tomography using B-scan-oriented polarization modulation method.
Fiber-based high-speed polarization-sensitive Fourier domain optical coherence tomography (PS-FD-OCT) is developed at 840 nm wavelength using polarization modulation method. The incident state of polarization is modulated along B-scan. The spectrometer has a polarizing beamsplitter and two line-CCD cameras operated at a line rate of 27.7 kHz. From the 0th and 1st orders of the spatial frequenci...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Applied optics
دوره 44 26 شماره
صفحات -
تاریخ انتشار 2005