A time-selective technique for free-field reciprocity calibration of condenser microphones.

نویسندگان

  • Salvador Barrera-Figueroa
  • Knud Rasmussen
  • Finn Jacobsen
چکیده

In normal practice, microphones are calibrated in a closed coupler where the sound pressure is uniformly distributed over the diaphragm. Alternatively, microphones can be placed in a free field, although in that case the distribution of sound pressure over the diaphragm will change as a result of the diffraction of the body of the microphone, and thus, its sensitivity will change. In the two cases, a technique based on the reciprocity theorem can be applied for obtaining the absolute sensitivity either under uniform pressure or free-field conditions. In this paper, signal-processing techniques are considered that improve the accuracy of the free-field calibration method. In particular, a fast Fourier transform (FFT)-based time-selective technique for removing undesired reflections from the walls of the measurement chamber has been developed and applied to the electric transfer impedance function between two microphones. The acoustic centers of the microphones have been determined from the "cleaned" transfer impedance values. Then, the complex free-field sensitivities of the microphones have been calculated. The resulting complex sensitivities and acoustic centers have proved to be in good agreement with previously published data, and this confirms the reliability of the time-selective technique, even in nonanechoic environments. Furthermore, the obtained results give a new reference for further comparisons, because they cover a frequency range with an accuracy that has not been obtained by previously published data.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Influence of ground-shield configuration in reciprocity calibration of laboratory standard microphones

The open-circuit sensitivity of condenser microphones, and in particular Laboratory Standard (LS) and Working Standard (WS) microphones, depend on the mechanical ground-shield configuration of the preamplifier. Therefore, the mechanical ground-shield configurations of preamplifiers for LS and WS microphones are defined in the IEC 61094 standard series. The sensitivity, dynamic range and acousti...

متن کامل

The National Standard for Sound Pressure in Air: Past, Present and Future

The CSIR-NML has been performing primary calibrations of laboratory standard 1” condenser microphones for the past decade. The semiautomated system was developed by Mr Owen Cramer during 1990. Reciprocity calibration of microphones is a very labor intensive process, relying heavily on the skills of the metrologist. The NML saw the need to expand and improve their capabilities in this area. This...

متن کامل

Calibration of the pressure sensitivity of microphones by a free-field method at frequencies up to 80 khz.

A free-field (FF) substitution method for calibrating the pressure sensitivity of microphones at frequencies up to 80 kHz is demonstrated with both grazing and normal-incidence geometries. The substitution-based method, as opposed to a simultaneous method, avoids problems associated with the nonuniformity of the sound field and, as applied here, uses a 1/4-in. air-condenser pressure microphone ...

متن کامل

A note on determination of the diffuse-field sensitivity of microphones using the reciprocity technique.

The diffuse-field response of a microphone is usually obtained by adding a random-incidence correction to the pressure response of the microphone. However, the random-incidence correction is determined from a relative measurement, and its accuracy depends not only on the relative response at all angles of incidence but also on the accuracy of the frequency response at normal incidence. By contr...

متن کامل

Measuring sound absorption using local field assumptions

This paper describes a novel three-dimensional sound intensity probe consisting of 8 MEMS (micro-electromechanical systems) microphones and a novel free-field calibration method. The use of MEMS-microphones allows for a very compact design compared to probes that employ 1/2-inch condenser microphones. A novel free-field calibration method, based on the principle of microphone interchange, is de...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • The Journal of the Acoustical Society of America

دوره 114 3  شماره 

صفحات  -

تاریخ انتشار 2003