Repair results of 2-tendon rotator cuff tears utilizing the transosseous equivalent technique.

نویسندگان

  • Paul M Sethi
  • Benjamin C Noonan
  • James Cunningham
  • Evan Shreck
  • Seth Miller
چکیده

BACKGROUND The purpose of this study was to examine the healing rate of 2-tendon rotator cuff tears repaired by the use of a transosseous-equivalent (TOE) suture bridge technique. MATERIALS AND METHODS Forty-three patients with combined supraspinatus and infraspinatus tendon tears underwent arthroscopic repair using TOE technique. Forty of these patients were then evaluated by MRI and clinical exam at a minimum of 1-year follow-up to determine the rate of healing of the repair and clinical outcomes associated with healing. RESULTS Eighty-three percent of the repairs demonstrated intact rotator cuff repairs at a mean of 16 months post-op. Larger tears (3.5 vs 2.8 cm) were associated with failure (P = .01), as was more advanced fatty infiltration (Goutallier 1.3 vs 0.3, P = .01). Age was not different between intact and nonintact tendons. Strength was the only clinical finding that differed between intact and nonintact tendons. CONCLUSION Two-tendon tears of the rotator cuff can heal at a high rate with the use of TOE suture bridge repair technique. Furthermore, tear size and Goutallier grading were negatively correlated with postoperative healing. The incremental improvement in the rate of observed rotator cuff healing still does not translate to statistical differences in the objective shoulder scoring systems.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Arthroscopic Double-Row Transosseous Equivalent Rotator Cuff Repair with a Knotless Self-Reinforcing Technique

BACKGROUND Rotator cuff tears are a significant cause of shoulder morbidity. Surgical techniques for repair have evolved to optimize the biologic and mechanical variables critical to tendon healing. Double-row repairs have demonstrated superior biomechanical advantages to a single-row. METHODS The preferred technique for rotator cuff repair of the senior author was reviewed and described in a...

متن کامل

Biomechanical evaluation of transosseous rotator cuff repair: do anchors really matter?

BACKGROUND Suture anchor fixation has become the preferred method for arthroscopic repairs of rotator cuff tears. Recently, newer arthroscopic repair techniques including transosseous-equivalent repairs with anchors or arthroscopic transosseous suture passage have been developed. PURPOSE To compare the initial biomechanical performance including ultimate load to failure and localized cyclic e...

متن کامل

“trAnsosseous-equivAlent” rotAtor cuff repAir

tears remains challenging, because the high re-tear rate following rotator cuff repair is due to multiple factors. Aspects such as poor tendon biology, muscular fatty infiltration and retraction, and nonanatomical repairs ultimately lead to inferior repair biomechanics. Although many of these factors remain beyond the control of the surgeon, certain repair constructs have been shown to decrease...

متن کامل

Clinical outcomes of single versus double row, transosseous equivalent arthroscopic rotator cuff repair

Rotator cuff tears are common and are expected to present with increasing frequency as the population ages. Various techniques in surgical repair have been described to improve clinical outcomes. A arthroscopic transosseous-equivalent double row repair is believed to be superior, with improved tendon to bone contact area and reduced gap formation. In our series of 143 patients, with 76 undergoi...

متن کامل

An Arthroscopic Knotless Technique for Anatomical Restoration of the Rotator Cuff and Superior Capsule: The Double-Layer Cinch Bridge

Rotator cuff repairs are the most common procedures in shoulder surgery, but still show long-term retear rates of up to 70%. Nonanatomic reconstruction is one possible cause of repair failure. The rotator cuff histologically consists of 5 separate layers of which 2 are macroscopically identifiable: the superior or tendinous layer and the inferior or capsule-ligamentous layer. In case of rotator...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of shoulder and elbow surgery

دوره 19 8  شماره 

صفحات  -

تاریخ انتشار 2010