A comparative evaluation of linear dimensional accuracy of the dies obtained using three conceptually different die systems in the fabrication of implant prosthesis: an in vitro study.
نویسندگان
چکیده
STATEMENT OF PROBLEM Given that meticulous implant prosthodontic procedures are recommended to obtain the best possible intraoral fit, the die systems used for multi implant casts warrant further investigation. Die stone expansion and errors introduced by removable die casts may exceed the accuracy required for the passive fit of implant prosthesis. PURPOSE The purpose of the study was to evaluate the linear dimensional accuracy between the implant master die and three conceptually different die systems such as Pindex system, Accu-trac precision die system, and Conventional brass dowel pin system. MATERIALS AND METHODS Thirty impressions of implant master die were made with polyether impression material. Ten experimental implant casts were fabricated for each of the three different die systems tested: Accu-trac precision die tray system, Pindex system, and conventional brass dowel pin system. The solid experimental casts were sectioned and then removed from the die system 30 times. Linear distances between all six possible distances were measured from one centre of the transfer coping to the other, using a co-ordinate measuring machine in millimeters up to accuracy of 0.5 microns. Data were tabulated and statistically analyzed by Binomial non parametric test using SPSS version 15. RESULTS Significant differences were found for distance A-B (P = 0.002), A-C ( P = 0.002), A-D (P value = 0.002), and B-D ( P = 0.021) in Conventional Dowel pin system however for Accu-trac precision die tray system, it was significant only for distance A-D (P = 0.002) but for Pindex system it was non-significant for all the distances measured. CONCLUSION Within the limitations of this study, use of Pindex system is recommended when sectioned dies are needed for a multi implant retained prosthesis.
منابع مشابه
Comparative Analysis of Dimensional Accuracy of Two Types of Silicone Impression Materials: Optosil and Elite-HD
Statement of the Problem: Understanding about impression materials, their properties, uses and manipulation can guide operators towards having more successful restorations. Purpose: The aim of this in vitro study was to compare the accuracy of a condensation silicone impression material, Optosil, and an addition poly siloxane impression material, Elite-HD. Materials and Method: A laboratory mod...
متن کاملبررسی مقایسهای دو سیستم Cone Beam CT به لحاظ دقت اندازهگیری خطی محلهای قراردهی ایمپلنت در مندیبل بهصورت In Vitro
Background and Objective: There are critical areas in the mandible that should be considered during implant placement such as inferior alveolar canal, mental foramen, and the root of the adjacent tooth. Two-dimensional images obtained from periapical, panoramic, and conventional tomography are considered in the evaluation of implant placement and bone quality. Cone-beam computed tomography (CBC...
متن کاملIn Vitro Evaluation of Fracture Resistance of Zirconia Restorations Veneered by Two Different Systems: Rapid Layer Technique and Zir/CAD/CAM
Background: This study aimed to assess the fracture resistance of zirconia restorations fabricated with rapid layer (RL group) technique and zirconia computer-aided design/computer-aided manufacturing (zir/CAD/CAM) system (ZC group). Methods:This study evaluated 30 all-ceramic crowns in two groups of 15. After fabricating the metal dies and scanning them ...
متن کاملDimensional accuracy of three impression materials by one-step and two-step impression techniques: An in vitro study
Introduction: An accurate impression is essential to create a well-fitted dental prosthesis. This study aimed to compare the dimensional accuracy of three elastomeric materials using one-step and two-step impression techniques. Methods: In this study, 20 impressions were fabricated for each Vinyl siloxane ether (Identium), condensation silicone (Speedex), and a...
متن کاملEffects of Water/Powder Ratio of Irreversible Hydrocolloid on Dimensional Stability of Impressions
Background and Aim: Water/powder ratio is effective on some properties of irreversible hydrocolloid impression materials. This study aimed to determine the ef-fects of water/powder ratio of irreversible hydrocolloid impression materials on di-mensional stability of impressions. Materials and Methods: In this in vitro experimental study, a metal model with two abutments as anchoring support for...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Indian journal of dental research : official publication of Indian Society for Dental Research
 
دوره 25 2 شماره
صفحات -
تاریخ انتشار 2014