DVH computation comparisons using conventional methods and optimized FFT algorithms for brachytherapy

نویسندگان

  • T. Kemmerer
  • M. Lahanas
  • N. Zamboglou
چکیده

In anatomy based optimization procedures for large volume implants the calculation of dose-volume histograms (DVH) accounts for the major part of the time involved and can be as long as a few hours. This time is proportional to the number of seeds or source dwell positions required for the implant. A procedure for the calculation of brachytherapy seed dose distribution calculation employing fast Fourier transforms (FFT) and the convolution theorem has been described by others and was supposed to significantly improve the speed of the dose distribution computation. Using new significantly improved FFT algorithms and various other optimization techniques we have compared the calculated differential and integral DVHs in HDR brachytherapy with a single stepping source using actual clinical implants. This is so that we could assess the efficiency and accuracy of the FFT method with that of conventional methods. Our results showed that the FFT based method of calculating DVHs in brachytherapy is comparable in speed with conventional dose calculation methods, but only for implants with more than 287 sources. It is therefore of limited practical use even for large implants. This result is in direct opposition to the claim by other authors.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Accelerating Signal Processing Algorithms Using Graphics Processors

There is increased interest in the use of graphics processing units (GPUs) for general purpose computation. This is because GPUs are almost two orders of magnitude faster in terms of floating point throughput compared to conventional CPUs. In this paper we investigate the use of graphics processing units for accelerating signal processing algorithms, specifically FIR filters and the FFT. We des...

متن کامل

Implementation of 3-D Anisotropy Corrected Fast Fourier Transform Dose Calculation around Brachytherapy Seeds

A routine dose computation around brachytherapy seeds employing the Fast Fourier Transform (FFT) has been demonstrated and likened to dose computations in a similar field based on the TG43 recommendations. In applying the FFT convolution model to dose computation, a dose convolution kernel which takes into consideration the anisotropy of the dose distribution around a brachytherapy source in th...

متن کامل

Real-valued fast Fourier transform algorithms

This tutorial paper describes the methods for constructing fast algorithms for the computation of the discrete Fourier transform (DFT) of a real-valued series. The application of these ideas to all the major fast Fourier transform (FFT) algorithms is discussed, and the various algorithms are compared. We present a new implementation of the real-valued split-radix FFT, an algorithm that uses few...

متن کامل

Treatment planning study of the 3D dosimetric differences between Co-60 and Ir-192 sources in high dose rate (HDR) brachytherapy for cervix cancer

PURPOSE To evaluate whether Co-60 is equivalent to Ir-192 for HDR cervical brachytherapy, through 3D-DVH dose comparisons in standard and optimised plans. Previous studies have only considered 2D dosimetry, point dose comparisons or identical loading. Typical treatment times and economics are considered. MATERIAL AND METHODS Plans were produced for eight cervix patients using Co-60 and Ir-192...

متن کامل

Patient's specific integration of OAR doses (D2 cc) from EBRT and 3D image‐guided brachytherapy for cervical cancer

The objective of this study was to assess the recommended DVH parameter (e.g., D2 cc) addition method used for combining EBRT and HDR plans, against a reference dataset generated from an EQD2-based DVH addition method. A revised DVH parameter addition method using EBRT DVH parameters derived from each patient's plan was proposed and also compared with the reference dataset. Thirty-one biopsy-pr...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2000