Increased sensitivity to low concentration gadolinium contrast by optimized heavily T2-weighted 3D-FLAIR to visualize endolymphatic space.

نویسندگان

  • Shinji Naganawa
  • Hisashi Kawai
  • Michihiko Sone
  • Tsutomu Nakashima
چکیده

PURPOSE To increase the sensitivity of 3-dimensional fluid-attenuated inversion recovery (3D-FLAIR) to low concentration gadolinium (Gd)-based contrast medium, we optimized sequence parameters on a phantom and evaluated the optimized sequence in patients suspicious for endolymphatic hydrops. MATERIALS AND METHODS All scans were performed on a 3-tesla magnetic resonance (MR) unit using a 32-channel head coil. We optimized sequence parameters using a phantom filled with diluted Gd and compared the optimized protocol with 3D-FLAIR using conventional turbo spin echo sequence (3D-FLAIR-CONV). Nine patients underwent scanning using the newly optimized sequence and 3D-FLAIR-CONV 4 hours after double-dose administration of intravenous Gd. We subjectively scored separation of endo- and perilymph space and measured contrast-to-noise ratio (CNR) between endo- and perilymph. RESULTS The optimized sequence in the phantom study consisted of: repetition time, 9000 ms; echo time, 540 ms; inversion time, 2400 ms; low constant readout flip angle, 120 degrees in the later part of the echo train. Image contrast became heavily T(2)-weighted (hT(2)W-3D-FLAIR). In patients, we recognized endolymphatic space for both the cochlea and vestibule significantly better by hT(2)W-3D-FLAIR than 3D-FLAIR-CONV (P<0.01). The mean CNR of the new method was also better than that of 3D-FLAIR-CONV (P<0.01). CONCLUSIONS The newly optimized hT(2)W-3D-FLAIR was more sensitive than the previous method to low concentration of Gd. Visualization of the endolymphatic space by double-dose administration of intravenous Gd would be more reliable using hT(2)W-3D-FLAIR.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Relationship between Contrast Enhancement of the Perivascular Space in the Basal Ganglia and Endolymphatic Volume Ratio

PURPOSE We routinely obtain the endolymphatic hydrops (EH) image using heavily T2-weighted three dimensional-fluid attenuated inversion recovery (hT2w-3D-FLAIR) imaging at 4 hours after intravenous administration of a single-dose of gadolinium-based contrast media (IV-SD-GBCM). While repeating the examination, we speculated that the contrast enhancement of the perivascular space (PVS) in the ba...

متن کامل

Visualization of White Matter Tracts Using a Non-Diffusion Weighted Magnetic Resonance Imaging Method: Does Intravenous Gadolinium Injection Four Hours Prior to the Examination Affect the Visualization of White Matter Tracts?

OBJECTIVES Visualization of white matter (WM)-tracts such as the corticospinal tract (CST), medial lemniscus (ML), and superior cerebellar peduncle (SCP) using delayed enhanced (DE)-heavily T2-weighted three-dimensional fluid-attenuated inversion-recovery (hT2w-3D-FLAIR) imaging has recently been reported. In that report, all patients were clinically suspected of having Ménière's disease, becau...

متن کامل

Contrast-enhanced magnetic resonance pancreatography with gadoteridol by heavily T2-weighted three-dimensional fluid-attenuated inversion recovery: preliminary results in healthy subjects

The purpose of this study was to investigate the feasibility of contrast-enhanced magnetic resonance (MR) pancreatography with intravenously administered gadolinium-based contrast material (GBCM) in healthy subjects. Eight healthy male subjects (age: 29-53 years old, median: 37 years old) were enrolled. Contrast-enhanced MR pancreatography was scanned with heavily T2-weighted three-dimensional ...

متن کامل

Semi-Quantitative vs. Volumetric Determination of Endolymphatic Space in Menière’s Disease Using Endolymphatic Hydrops 3T-HR-MRI after Intravenous Gadolinium Injection

Magnetic resonance imaging enhances the clinical diagnosis of Menière's disease. This is accomplished by in vivo detection of endolymphatic hydrops, which are graded using different semi-quantitative grading systems. We evaluated an established, semi-quantitative endolymphatic hydrops score and with a quantitative method for volumetric assessment of the endolymphatic size. 11 patients with Meni...

متن کامل

Comparison of the added value of contrast-enhanced 3D fluid-attenuated inversion recovery and magnetization-prepared rapid acquisition of gradient echo sequences in relation to conventional postcontrast T1-weighted images for the evaluation of leptomeningeal diseases at 3T.

BACKGROUND AND PURPOSE The usefulness of contrast-enhanced 3D T2-FLAIR MR imaging for the evaluation of leptomeningeal diseases has not been systematically investigated. The purpose of this study was to assess the value added by contrast-enhanced 3D T2-FLAIR and MPRAGE sequences to conventional postcontrast T1-weighted images in the evaluation of leptomeningeal diseases. We also undertook in vi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Magnetic resonance in medical sciences : MRMS : an official journal of Japan Society of Magnetic Resonance in Medicine

دوره 9 2  شماره 

صفحات  -

تاریخ انتشار 2010