A new valveless all-purpose ventilator. Description and laboratory evaluation.

نویسندگان

  • M K Chakrabarti
  • J G Whitwam
چکیده

A ventilator, of new design, is described which has been evaluated on a lung model and in animals. It is simple, versatile, inexpensive and easy to sterilize. A single breathing tube is used in which the respiratory gas is introduced near the patient's airway while a jet in a more distal part of the tube drives the respiratory gas into the patient's lungs. Provided the internal volume between the respiratory gas inlet and the driving jet is at least one tidal volume, the driving gas does not take part in respiratory gas exchange. During controlled ventilation only normal ventilation volumes of respiratory fresh gas are required during both normal and high frequency ventilation. It can be used for any age group with any desired respiratory gas, and is suitable for use in the operating theatre and the intensive care unit. As there are no valves in the breathing system, which is open to the atmosphere at all times, complicated systems for synchronizing the machine with spontaneous breathing are not required. PEEP, NEEP, CPAP and IMV are applied easily.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Assessment of a new valveless infant ventilator.

A new valveless ventilator, which uses an air jet to provide the driving force for positive pressure ventilation, was used on 13 newborn babies (10 of very low birthweight) who had severe respiratory disease. The ventilator differs from 'true' jet ventilators in that its driving gas does not take part in gas exchange. Functionally it is a pressure pre-set, time-cycled ventilator, whose performa...

متن کامل

Comparison of two ventilators used with the T-piece in paediatric anaesthesia.

The Nuffield 200 ventilator was compared with a new valveless ventilator (CW 200) in 20 children undergoing general anaesthesia for paediatric surgery. The new ventilator incorporates design features which overcome the main disadvantages of the Nuffield 200 and make it an inherently safer machine. At identical ventilator settings it produced a significantly greater tidal volume with a reduction...

متن کامل

Development of an automated high-temperature valveless injection system for online gas chromatography

A reliable method of sample introduction is presented for online gas chromatography with a special application to in situ field portable atmospheric sampling instruments. A traditional multi-port valve is replaced with a valveless sample introduction interface that offers the advantage of long-term reliability and stable sample transfer efficiency. An engineering design model is presented and t...

متن کامل

Objective evaluation of neonatal ventilators.

Choosing which ventilator to purchase can dramatically affect what type of care patients get, practitioners’ working environment, and the hospital’s “bottom line.” Choosing a ventilator is a complicated process, often confounded by competing stakeholders. Trying to balance the desires of the hospital management, physicians, and respiratory therapists can be tricky. Getting the right equipment f...

متن کامل

Laboratory and clinical evaluation of a new volume ventilator.

A three phase laboratory and clinical evaluation of a new fluidically controlled volume ventilator (Ohio 550) was undertaken to determine if this more compact, less complex and less costly unit retained the multiple advantages which have been established for volume ventilators in the continuous ventilatory support of patients in respiratory failure. Inspired volume, peak pressure, and flow rate...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • British journal of anaesthesia

دوره 55 10  شماره 

صفحات  -

تاریخ انتشار 1983