“Edge Effect” of P Radioactive Stents Is Caused by the Combination of Chronic Stent Injury and Radioactive Dose Falloff

نویسندگان

  • Willem J. van der Giessen
  • Evelyn Regar
  • Patrick W. Serruys
چکیده

Background—Radioactive stents have been reported to reduce in-stent neointimal thickening. An unexpected increase in neointimal response was observed, however, at the stent-to-artery transitions, the so-called “edge effect.” To investigate the factors involved in this edge effect, we studied stents with 1 radioactive half and 1 regular nonradioactive half, thereby creating a midstent radioactive dose-falloff zone next to a nonradioactive stent-artery transition at one side and a radioactive stent-artery transition at the other side. Methods and Results—Half-radioactive stents (n520) and nonradioactive control stents (n510) were implanted in the coronary arteries of Yucatan micropigs. Animals received aspirin and clopidogrel as antithrombotics. After 4 weeks, a significant midstent stenosis was observed by angiography in the half-radioactive stents. Two animals died suddenly because of coronary occlusion at this mid zone at 8 and 10 weeks. At 12-week follow-up angiography, intravascular ultrasound and histomorphometry showed a significant neointimal thickening at the midstent dose-falloff zone of the half-radioactive stents, but not at the stent-to-artery transitions at both extremities. Such a midstent response (mean angiographic late loss 1.0 mm) was not observed in the nonradioactive stents (mean loss 0.4 to 0.6 mm; P,0.01). Conclusions—The edge effect of high-dose radioactive stents in porcine coronary arteries is associated with the combination of stent injury and radioactive dose falloff. (Circulation. 2001;104:2236-2241.)

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

"Edge Effect" of (32)p radioactive stents is caused by the combination of chronic stent injury and radioactive dose falloff.

BACKGROUND Radioactive stents have been reported to reduce in-stent neointimal thickening. An unexpected increase in neointimal response was observed, however, at the stent-to-artery transitions, the so-called "edge effect." To investigate the factors involved in this edge effect, we studied stents with 1 radioactive half and 1 regular nonradioactive half, thereby creating a midstent radioactiv...

متن کامل

Edge Restenosis After Implantation of High Activity P Radioactive b-Emitting Stents

Background—A high restenosis rate has been reported at the edges (“edge restenosis”) of P radioactive stents with an initial activity level of 3 to 12 mCi. This edge effect might be due to balloon injury and to a low dose of radiation at the stent margins. The aim of this study was to evaluate whether the implantation of P radioactive stents with a higher activity level (12 to 21 mCi) combined ...

متن کامل

Dosimetric comparison between four kinds of radioactive esophageal stents to be used in the treatment of advanced esophageal cancers using Monte Carlo simulation

Finding accurate methods to be employed for the treatment of esophageal cancers is of especial interest for researchers, due to the sensitivity of this tissue. Recently radioactive stents loaded with I-125 brachytherapy seeds have been widely investigated for the treatment of advanced esophageal cancer. It is necessary to investigate the dose distribution of any radioactive esophageal stents be...

متن کامل

Dose-Response Effects of P Radioactive Stents in an Atherosclerotic Porcine Coronary Model

Background—Experimental studies have demonstrated that P radioactive stents reduce neointimal formation at 28 days in porcine iliac and coronary arteries. Our objective was to determine the long-term dose-response effects of 1.0to 12.0-mCi P radioactive stents in a porcine atherosclerotic coronary model. Methods and Results—Control (n519) and 1.0to 12.0-mCi P radioactive (n543) stents (total, n...

متن کامل

Dose-response effects of 32P radioactive stents in an atherosclerotic porcine coronary model.

BACKGROUND Experimental studies have demonstrated that 32P radioactive stents reduce neointimal formation at 28 days in porcine iliac and coronary arteries. Our objective was to determine the long-term dose-response effects of 1.0- to 12.0-microCi 32P radioactive stents in a porcine atherosclerotic coronary model. METHODS AND RESULTS Control (n=19) and 1.0- to 12.0-microCi 32P radioactive (n=...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2001