Digital anatomical measurements and crucial bending areas of the fixation route along the inferior border of the arcuate line for pelvic and acetabular fractures
نویسندگان
چکیده
BACKGROUND Better understanding of three-dimensional (3D) morphology of the pelvis at the area of inferior border of the arcuate line is very important, which could guide the surgeons to treat pelvic and acetabular fractures more efficiently. The objective of this study is to provide references for screw placement and design of anatomical internal fixators for the fixation route along the pelvic inferior border of the arcuate line. METHODS Seventy five cases of computed tomography (CT) scan data were collected using Medical Image Database in Shanghai General Hospital between December 2009 and November 2010. 44 males and 31 females, aging from 21 to 91 years (average: 57.8 years) were enrolled. Using MIMICS 13.0, these data were used for three dimensional (3D) reconstructions of pelvic model. A curve from the pubic tubercle, along the inferior border of the arcuate line, to the sacroiliac joint was depicted and then divided into 11 equal parts. The measurements of whole length of the curve, the radius of the curvature and the thickness of bone at each decile point were performed, respectively. RESULTS The thinnest bone thickness at acetabular area was 17.24 ± 2.90 mm and 9.94 ± 2.69 mm for male and female, respectively. The radius of curvature at the decile points 1, 8 and 10 were smaller compared with the surrounding points. CONCLUSIONS Using a screw shorter than 10 mm perpendicular to the bone surface along the inferior border of the arcuate line can avoid intra-articular screw penetration. There should be more recontouring of the plate at the areas of pubic tubercle and posterior edge of the acetabulum when placing a fixator along this fixation route. This study provides solid guidance for pelvic and acetabular surgeries as well as designing of anatomical fixators along inferior border fixation route at this area.
منابع مشابه
The safe screw path along inferior border of the arcuate line at acetabular area: an anatomical study based on CT scans
BACKGROUND Misplaced screw during the internal fixation of acetabular fractures may penetrate the hip joint which might cause chondrolysis and traumatic osteoarthritis in the future. This study aims to acquire the safe path for screw insertion along inferior border of the arcuate line fixation route at acetabular area. METHODS Computed tomography (CT) scans of 98 patients without pelvic traum...
متن کاملClinical Results of Percutaneous Fixation of Pelvic and Acetabular Fractures: A Minimally Invasive Internal Fixation Technique
Background: The pelvic ring fractures (PRF) and acetabular fractures (AF) are among the major orthopedic injuriesassociated with high rates of morbidity and mortality. Open surgical stabilization is the standard treatment for themajority of these complications. Percutaneous minimally invasive surgical stabilization of the fractures has become anaccepted treatment method for th...
متن کاملDigital anatomical measurements of safe screw placement at superior border of the arcuate line for acetabular fractures
BACKGROUND Screw penetration into hip joint is a severe complication during acetabular fracture surgery, which might result in osteoarthritis and chondrolysis. The purpose of this study was to obtain the safe and effective screw angles and lengths at acetabular area of the fixation route along the superior border of the arcuate line. METHODS A total of 98 uninjured pelvises of Chinese adults ...
متن کاملRisk of Spermatic Cord Injury During Anterior Pelvic Ring and Acetabular Surgery: An Anatomical Study
Background: Anterior pelvic ring surgery includes a variety of plating techniques and insertion of retrograde superior pubic ramus screws. Anterior acetabular surgery also includes fixation through an ilioinguinal or Stoppa approach. These exposures risk injury to the spermatic cord and accompanying genital branch of the genitofemoral nerve. The primary aim of this study was to identify the d...
متن کاملمقایسه تفاوت لندمارک های آناتومیک دو تکنیک رادیوگرافی لترال سفالومتری دیجیتال و معمولی به روش ترسیم دستی در جمجمه های انسانی
Background and purpose: Digital radiography has led to many improvements in radiology. Despite many advantages there are different ideas in determining anatomical landmarks which results in some errors in cephalometric analyses. The aim of this study was to determine the degree of identification differences of anatomical landmarks by conventional and digital lateral cephalometric techniques usi...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 17 شماره
صفحات -