PulStar differential compliance spinal instrument: a randomized interexaminer and intraexaminer reliability study.

نویسندگان

  • Robert A Leach
  • Patrick L Parker
  • Paul S Veal
چکیده

OBJECTIVE To provide an entry-level, new technology reliability assessment of the PulStar computer-assisted, differential compliance spinal instrument. SUBJECTS Eighteen college students (9 male and 9 female) were recruited by announcements and personal contacts. METHODS Following approval of the consent process by the Institutional Review Board of Mississippi State University, a PulStar Function Recording and Analysis System (PulStarFRAS) device was evaluated for clinical reliability. Two examiners, blinded from data collection, used the instrument on individual subjects in random order (lying prone with their backs exposed) to administer light impulses (approximately equal to .9 J which produced a 3- to 4-lb force) at each segmental level throughout the cervical, dorsal, and lumbar spine using probe tips spaced 3 cm apart, straddling the spinous processes, while a computer recorded the findings (resistance on a scale of 0 to 25.5 lb force). Data were analyzed by Exploratory Data Analysis (EDA) with analysis of variance (ANOVA) testing and by use of the intraclass correlation coefficient (ICC). In addition, a mean test (ANOVA) was conducted to determine if a trend in variation occurred as a result of repeated light thrusts to the spine, independent of variance explained by different examiners. RESULTS Using EDA analysis and ANOVA, intraexaminer reliability for the 2 practitioners was very high but not perfect. This was confirmed by ICC statistics demonstrating good to excellent reliability for both practitioners (0.89 for the experienced practitioner, 0.78 for the newly trained practitioner). Interexaminer reliability of PulStar was similarly very high but not perfect based on EDA/ANOVA analysis and good to excellent (ICC = 0.87). CONCLUSION The PulStar mechanical adjusting device set to analysis mode appears to have good to excellent reliability when used by either an experienced or a novice (but trained) examiner. In addition, as a measure for resistance to a light thrust or spinal compliance, reliability was similarly good to excellent between the 2 doctors using the PulStar instrument.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Reliability of spinal palpation for diagnosis of back and neck pain: a systematic review of the literature.

STUDY DESIGN A systematic review. OBJECTIVES To determine the quality of the research and assess the interexaminer and intraexaminer reliability of spinal palpatory diagnostic procedures. SUMMARY OF BACKGROUND DATA Conflicting data have been reported over the past 35 years regarding the reliability of spinal palpatory tests. METHODS The authors used 13 electronic databases and manually se...

متن کامل

The reliability of palpating the posterior superior iliac spine: a systematic review.

INTRODUCTION Among pelvic landmarks routinely palpated by manual therapists, the posterior superior iliac spines (PSISs) are particularly important. In addition to serving as landmarks for identifying possible pelvic torsion, contacting the PSISs is integral to many other static and dynamic pelvic palpatory procedures. The primary study goal was to systematically review the literature on the in...

متن کامل

Anterior Superior Iliac Spine Asymmetry Assessment

Objective: The purpose of this study was to develop a novel pelvic model and determine the accuracy and the interand intraexaminer reliability of anterior superior iliac spine (ASIS) positional asymmetry assessment from both sides of the model by osteopathic predoctoral fellows and osteopathic physicians and to evaluate the effect of training. Methods: Five osteopathic predoctoral fellows and 5...

متن کامل

Paraspinal skin temperature patterns: an interexaminer and intraexaminer reliability study.

BACKGROUND Paraspinal thermography is used by chiropractors as an aid in assessing the presence of vertebral subluxation. Few reliability studies have been carried out, with mixed results. Digital infrared scanning equipment is now available with location tracking that may enhance reproducibility. Digitized scans enable a computer-aided interpretation of thermographic patterns. OBJECTIVE To a...

متن کامل

Anterior superior iliac spine asymmetry assessment on a novel pelvic model: an investigation of accuracy and reliability.

OBJECTIVE The purpose of this study was to develop a novel pelvic model and determine the accuracy and the inter- and intraexaminer reliability of anterior superior iliac spine (ASIS) positional asymmetry assessment from both sides of the model by osteopathic predoctoral fellows and osteopathic physicians and to evaluate the effect of training. METHODS Five osteopathic predoctoral fellows and...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of manipulative and physiological therapeutics

دوره 26 8  شماره 

صفحات  -

تاریخ انتشار 2003