An electrically-activated dynamic tissue-equivalent phantom for assessment of diffuse optical imaging systems.
نویسندگان
چکیده
A novel design of solid dynamic phantom with tissue-like optical properties is presented, which contains variable regions of contrast which are activated electrically. Reversible changes in absorption are produced by localized heating of targets impregnated with thermochromic pigment. A portable, battery-operated prototype has been constructed, and its optical and temporal characteristics have been investigated. The phantom has been developed as a means of assessing the performance of diffuse optical imaging systems, such as those used to monitor haemodynamic changes in the brain and other tissues. Images of the phantom have been reconstructed using data acquired with a continuous wave optical topography system.
منابع مشابه
A dynamic optical imaging phantom based on an array of semiconductor diodes.
An electrically-activated phantom for evaluating diffuse optical imaging systems has been designed based on an array of semiconductor diodes which are used to heat a thermochromic dye embedded in a solidified polyester resin with tissue-like optical properties. The array allows individual diodes to be addressed sequentially, thus simulating the movement of a small volume of contrasting optical ...
متن کاملEvaluation of Reflection Optical Imaging Characteristics Using Fluorescence with Near Infrared Wavelength at Different Depths of Tissue Equivalent Phantom
متن کامل
Spectral Separation of Quantum Dots within Tissue Equivalent Phantom Using Linear Unmixing Methods in Multispectral Fluorescence Reflectance Imaging
Introduction Non-invasive Fluorescent Reflectance Imaging (FRI) is used for accessing physiological and molecular processes in biological media. The aim of this article is to separate the overlapping emission spectra of quantum dots within tissue-equivalent phantom using SVD, Jacobi SVD, and NMF methods in the FRI mode. Materials and Methods In this article, a tissue-like phantom and an optical...
متن کاملDesign, Construction and Evaluation of an Anthropomorphic Head Phantom for Assessment of Image Distortion in Stereotactic Radiosurgery Planning Systems
Introduction: In recent years, the use of magnetic resonance (MR) images in radiation treatment planning has drawn considerable attention. However, although the extent of a tumor can be determined in great detail on MR images, the geometric accuracy of these images is limited by distortions stemming from the inhomogeneity of the static background magnetic field, the nonlineari...
متن کاملA tissue equivalent phantom for simultaneous near-infrared optical tomography and EEG
We describe a phantom which enables EEG and near-infrared optical tomography to be performed simultaneously over the same volume. The phantom provides a surface electrical contact impedance comparable to that of the human scalp, whilst also possessing an optical scattering coefficient and electrical conductivity equivalent to that of brain tissue. The construction of the phantom is described, a...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Physics in medicine and biology
دوره 53 2 شماره
صفحات -
تاریخ انتشار 2008