Cardiac output and mixed venous O2 content measurements by a tracer bolus method: animal validation study.

نویسندگان

  • J S Clark
  • Y J Lin
  • M J Criddle
  • R Jones
  • E Koppert
  • P Swier
چکیده

A bolus method for noninvasive measurement of cardiac output (CO) and mixed venous oxygen content (O2) has been tested against absolute CO and O2 standards in dogs. No statistical differences in CO were found between bolus method and electromagnetic flowmeter measurement comparisons in an 18-dog study in which CO varied from 0. 5 to 3.0 l/min. The SD for all paired differences was 0.14 l/min; however, data averaging over 10-min intervals were found to reduce the CO measurement uncertainty to <0.08 l/min. The ability of the bolus method to follow rapid CO changes, experimentally produced by control of a pump (surgically placed between the superior and inferior vena cava and the right atrium), was documented and found to satisfy CO monitoring requirements of unstable subjects. O2 bolus values were found to be statistically equivalent to reference measurements.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Cardiac output and mixed venous oxygen content measurements by a tracer bolus method: theory.

We present a bolus method of inert-gas delivery to the lungs that facilitates application of multiple inert gases and the multiple inert-gas-exchange technique (MIGET) model to noninvasive measurements of cardiac output (CO) and central mixed venous oxygen content Reduction in recirculation error is made possible by 1) replacement of sinusoidal input functions with impulse inputs and 2) replace...

متن کامل

Validity of Peripheral Capillary Oxygen Saturation and Normal Mixed Venous Oxygen Tension in Measurement of O2 Content

Background The change in venous oxygen saturation occurs earlier, and even its reduction is faster than arterial oxygen saturation. The aim of this study was to validate SvO2 and PvO2 for O2 content measurement in children hospitalized w...

متن کامل

Pressure recording analytical method for measuring cardiac output in critically ill children: a validation study.

BACKGROUND Pressure recording analytical method (PRAM) is a novel, arterial pulse contour-based method for measuring cardiac output (CO). Validation studies of PRAM in children are few, and have not assessed both absolute accuracy and ability to track changes in CO across a broad case mix. We aimed to compare CO as measured by PRAM with that using a transpulmonary dilution method in a cohort of...

متن کامل

A new indirect method for measuring arteriovenous O2 content difference and cardiac output from O2 and CO2 concentrations by rebreathing air.

A new indirect method for measuring the arteriovenous O2 content difference (avDO2) was developed. The avDO2 was calculated by dividing the gradient of the CO2 dissociation curve by that of a gas exchange ratio against PCO2. The latter slope was obtained from O2 and CO2 concentrations in rebreathing air. The validity of the method was tested preliminarily in human subjects by comparing the card...

متن کامل

Effects of arterial oxygen tension and cardiac output on venous saturation: a mathematical modeling approach

OBJECTIVES Hemodynamic support is aimed at providing adequate O2 delivery to the tissues; most interventions target O2 delivery increase. Mixed venous O2 saturation is a frequently used parameter to evaluate the adequacy of O2 delivery. METHODS We describe a mathematical model to compare the effects of increasing O2 delivery on venous oxygen saturation through increases in the inspired O2 fra...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of applied physiology

دوره 85 2  شماره 

صفحات  -

تاریخ انتشار 1998