Intermittent saline flushes or continuous saline infusion: what works better when heparin-free dialysis is recommended?

نویسنده

  • Edward Zimbudzi
چکیده

INTRODUCTION Coagulation-free dialysis, also commonly known as "heparin-free" dialysis, can be a challenging procedure as it increases the risk of clotting the dialysis circuit. Utilizing a better saline flushing technique can lead to improved patient outcomes as well as huge financial benefits to the health institution. The purpose of this study was to compare the effectiveness of continuous saline infusion (CSI) and intermittent saline flushing (ISF) in preventing clotting of the dialysis extracorporeal circuit (ECC). METHODS Fifty heparin-free treatments were randomized into two treatment arms, namely CSI and ISF. Predialysis full blood count and coagulation studies were performed for all patients. During ISF, 100 mL saline was infused via the arterial line every 30 minutes while occluding the blood inlet line. Normal saline was infused into the ECC at a rate of 200 mL/hour throughout the duration of dialysis under CSI. The ECC was inspected for clotting and graded accordingly post-dialysis. RESULTS Seventy-six percent of the CSI treatments were completed without losing the ECC while 52% of the ISF treatments were also successful. Patients who were treated with CSI were less likely to have clotted ECCs (odds ratio 3.4, 95% CI, 1.04 to 11.2; P = 0.04). No significant differences existed between the two groups' hematological factors that could influence clotting, such as hemoglobin and platelets. CONCLUSION This study demonstrates that, when heparin-free dialysis is indicated, CSI might be a better method of preventing the ECC from clotting. There is a greater chance of realizing long-term benefits to patients and the health service with the CSI method since there is a likelihood of a reduction in the use of erythropoietin-stimulating agents and blood transfusions with the CSI method.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Rationale and design of the HepZero study: a prospective, multicenter, international, open, randomized, controlled clinical study with parallel groups comparing heparin-free dialysis with heparin-coated dialysis membrane (Evodial) versus standard care: study protocol for a randomized controlled trial

BACKGROUND Anticoagulation for chronic dialysis patients with contraindications to heparin administration is challenging. Current guidelines state that in patients with increased bleeding risks, strategies that can induce systemic anticoagulation should be avoided. Heparin-free dialysis using intermittent saline flushes is widely adopted as the method of choice for patients at risk of bleeding,...

متن کامل

Hemodialysis without Systemic Anticoagulation: A Prospective Randomized Trial to Evaluate 3 Strategies in Patients at Risk of Bleeding

OBJECTIVE In this clinical trial, we aimed to compare three means of performing chronic hemodialysis in patients with contra-indication to systemic heparinization. METHODS This open-label monocentric randomized « n-of-one » trial, conducted in a single tertiary care center, recruited chronic hemodialysis patients with a contra-indication to systemic heparinization for at least 3 consecutive s...

متن کامل

بررسی مقایسه‌ای تاثیر 2 روش تجویز هپارین به صورت مداوم و متناوب بر روی زمان ترومبوپلاستین نسبی

Comparative Study of Continuous and Intermittent Administration of Heparin on APTT (Activated Partial Thromboplastin Time) I II *A. Adib, MD B. Fatourchi, MD Abstract There are many different doses and protocols of heparin injection for treatment or prevention of many thrombotic diseases. The present interventional experimental(Clinical trial) study was conducted to compare the effect of contin...

متن کامل

Results of the HepZero study comparing heparin-grafted membrane and standard care show that heparin-grafted dialyzer is safe and easy to use for heparin-free dialysis.

Heparin is used to prevent clotting during hemodialysis, but heparin-free hemodialysis is sometimes needed to decrease the risk of bleeding. The HepZero study is a randomized, multicenter international controlled open-label trial comparing no-heparin hemodialysis strategies designed to assess non-inferiority of a heparin grafted dialyzer (NCT01318486). A total of 251 maintenance hemodialysis pa...

متن کامل

Efficacy of normal saline versus heparinized saline solution for locking catheters of totally implantable long-term central vascular access devices in adult cancer patients.

BACKGROUND Heparin solution is routinely used to maintain the patency of infusion devices. Literature supports the alternative use of normal saline solution for flushing and locking intravenous infusion devices especially for pediatric patients. There is uncertainty regarding safety and efficacy of this policy for intermittent locking of implanted ports. OBJECTIVE This study evaluates efficac...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 6  شماره 

صفحات  -

تاریخ انتشار 2013