Five-degree-of-freedom manipulation of an untethered magnetic device in fluid using a single permanent magnet with application in stomach capsule endoscopy

نویسندگان

  • Arthur W. Mahoney
  • Jake J. Abbott
چکیده

This paper demonstrates magnetic three-degree-of-freedom (3-DOF) closed-loop position and 2-DOF open-loop orientation control of a mockup magnetic capsule endoscope in fluid with a single permanent magnet positioned by a commercial 6-DOF robotic manipulator, using feedback of only the 3-DOF capsule position measured by a localization system, with application in capsule endoscopy of a fluid-distended stomach. We analyze the kinematics of magnetic manipulation using a single permanent magnet as the end-effector of a serial-link robot manipulator, and we formulate a control method that enables the capsule’s position and direction to be controlled when the robot manipulator is not in a kinematic singularity, and that sacrifices control over the capsule’s direction to maintain control over the capsule’s position when the manipulator enters a singularity. We demonstrate the method’s robustness to a reduced control rate of 25 Hz, reduced localization rates down to 30 Hz, deviation in the applied magnetic field from that expected, and the presence of manipulator singularities. Five-DOF manipulation of an untethered magnetic device has been previously demonstrated by electromagnetic systems only.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

5-DOF Manipulation of a Magnetic Capsule in Fluid using a Single Permanent Magnet: Proof-of-Concept for Stomach Endoscopy

Magnetic manipulation of capsule endoscopes has the potential to make current gastrointestinal screening procedures faster, safer, and less invasive. To date, two electromagnetic systems have been developed with the ability to perform five-degree-of-freedom (5-DOF) manipulation of an untethered magnetic device such as a magnetic capsule endoscope: the OctoMag system consists of eight electromag...

متن کامل

5-DOF Manipulation of an Untethered Magnetic Device in Fluid using a Single Permanent Magnet

This paper presents a three degree-of-freedom (3DOF) closed-loop position and 2-DOF open-loop orientation control method for an untethered mockup magnetic capsule endoscope in fluid with a single permanent magnet positioned by a commercial robotic manipulator and a 3-DOF capsuleposition localization system. Using traditional methods known to roboticists, we study the kinematics of untethered ma...

متن کامل

Magnetic manipulation with several mobile coils towards gastrointestinal capsular endoscopy

Traditional techniques of endoscopy based on flexible endoscopes are fairly reliable but poorly tolerated by patients and do not give access to the small bowel. It has been demonstrated that magnetic fields are usable for manipulating an untethered magnet, either using fixed coils or mobile permanent magnets. We introduce a novel approach for magnetic manipulation and present the preliminary re...

متن کامل

Advanced Methods for Controlling Untethered Magnetic Devices Using Rotating Magnetic Fields

This dissertation presents results documenting advancements on the control of untethered magnetic devices, such as magnetic “microrobots” and magnetically actuated capsule endoscopes, motivated by problems in minimally invasive medicine. This dissertation focuses on applying rotating magnetic fields for magnetic manipulation. The contributions include advancements in the way that helical micros...

متن کامل

Closed Loop Control of a Tethered Magnetic Capsule Endoscope

Magnetic field gradients have repeatedly been shown to be the most feasible mechanism for gastrointestinal capsule endoscope actuation. An inverse quartic magnetic force variation with distance results in large force gradients induced by small movements of a driving magnet; this necessitates robotic actuation of magnets to implement stable control of the device. A typical system consists of a s...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • I. J. Robotics Res.

دوره 35  شماره 

صفحات  -

تاریخ انتشار 2016