A study of balloon type, system constraint and artery constitutive model used in finite element simulation of stent deployment

نویسنده

  • A Schiavone
چکیده

Background: Finite element is an effective tool to simulate stent expansion inside stenotic arteries, which provides an insightful understanding of the biomechanical behaviour of the whole stent-artery system during the procedure. The choice of balloon type, system constraint and artery constitutive model plays an important role in finite element simulation of stent deployment. Methods: Commercial finite element package ABAQUS was used to model the expansion of Xience stent inside a diseased artery with 40% stenosis. The arterial wall, consisting of intima, media and adventitia layers, and the stenotic plaque were described by different hyperelastic models. Both folded and rubber balloons were considered and inflated with a linearly increasing pressure of 1.4 MPa. Simulations were also carried out by considering free, partially and fully constrained arteries. Results: Folded balloon produces sustained stent expansion under a lower pressure when compared to rubber balloon, leading to increased stress level and enhanced final expansion for the system. Fully constrained artery reduces the stent expansion when compared to free and partially constrained arteries, due to the increased recoiling effect. Stress in the artery-plaque system has higher magnitude for stent expansion in a free artery due to more severe stretch. Calcified plaque limits stent expansion considerably when compared to hypocellular plaque. The negligence of the second stretch invariant in the strain energy potential leads to the disappearance of saturation behaviour during stent expansion. The use of anisotropic artery model reduces the system expansion at peak pressure when compared to the isotropic model, but with an increased final diameter due to reduced recoiling effect. The stress distribution in the artery-plaque system is also different for different combinations of artery and plaque constitutive models. Conclusions: Folded balloon should be used in the simulation of stent deployment, with the artery partially constrained using spring elements with a proper stiffness constant. The blood vessel should be modelled as a three-layer structure using a hyperelastic potential that considers both the first and second stretch invariants as well as the anisotropy. The composition of the plaque also has to be considered due to its major effect on stent deployment.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Chip Formation Process using Finite Element Simulation “Influence of Cutting Speed Variation”

The main aim of this paper is to study the material removal phenomenon using the finite element method (FEM) analysis for orthogonal cutting, and the impact of cutting speed variation on the chip formation, stress and plastic deformation. We have explored different constitutive models describing the tool-workpiece interaction. The Johnson-Cook constitutive model with damage initiation and damag...

متن کامل

Balloon-artery interactions during stent placement: a finite element analysis approach to pressure, compliance, and stent design as contributors to vascular injury.

Endovascular stents expand the arterial lumen more than balloon angioplasty and reduce rates of restenosis after coronary angioplasty in selected patients. Understanding the factors involved in vascular injury imposed during stent deployment may allow optimization of stent design and stent-placement protocols so as to limit vascular injury and perhaps reduce restenosis. Addressing the hypothesi...

متن کامل

Optimal Stent Expansion by Stent Balloon Multiple Inflation at Nominal Pressure in Resistant Lesions: A New Technique

Introduction: This study aimed to evaluate the effects of four-time inflation of the stent balloon at nominal pressure on optimal stent expansion in resistant lesions. Materials and Methods: This interventional study was conducted on 39 patients with coronary artery lesions, in whom Zotarolimus-eluting stents (N=20), Paclitaxel-eluting stents (N=11) and other stents (N=8) were deployed four tim...

متن کامل

Finite element analysis of balloon-expandable coronary stent deployment: influence of angioplasty balloon configuration.

Today, the majority of coronary stents are balloon-expandable and are deployed using a balloon-tipped catheter. To improve deliverability, the membrane of the angioplasty balloon is typically folded about the catheter in a pleated configuration. As such, the deployment of the angioplasty balloon is governed by the material properties of the balloon membrane, its folded configuration and its att...

متن کامل

Multiobjective Nonlinear Shape Optimization of Stent Based on Evolution Principles

The treatment of atherosclerotic stenoses is accomplished by a well-established interventional method called Percutaneous Transluminal Angioplasty (PTA). Generally, this procedure is accompanied with the deployment of small tube shape structure to support the wall of the injured artery and improve the limitations of balloon angioplasty, such as restenosis and abrupt closure. Numerous computatio...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2015