EEG deblurring techniques in a clinical context.
نویسندگان
چکیده
OBJECTIVES EEG scalp potential distributions recorded in humans are affected by low spatial resolution and by the dependence on the electrical reference used. High resolution EEG technologies are available to drastically increase the spatial resolution of the raw EEG. Such technologies include the computation of surface Laplacian (SL) of the recorded potentials, as well as the use of realistic head models to estimate the cortical sources via linear inverse procedure (low resolution brain electromagnetic tomography, LORETA). However, these deblurring procedures are generally used in conjunction with EEG recordings with 64-128 scalp electrodes and with realistic head models obtained via sequential magnetic resonance images (MRIs) of the subjects. Such recording setup it is not often available in the clinical context, due to both the unavailability of these technologies and the scarce compliance of the patients with them. In this study we addressed the use of SL and LORETA deblurring techniques to analyze data from a standard 10-20 system (19 electrodes) in a group of Alzheimer disease (AD) patients. METHODS EEG data related to unilateral finger movements were gathered from 10 patients affected by AD. SL and LORETA techniques were applied for source estimation of EEG data. The use of MRIs for the construction of head models was avoided by using the quasi-realistic head model of the Brain Imaging Neurology Institute of Montreal. RESULTS A similar cortical activity estimated by the SL and LORETA techniques was observed during an identical time period of the acquired EEG data in the examined population. CONCLUSIONS The results of the present study suggest that both SL and LORETA approaches can be usefully applied in the clinical context, by using quasi-realistic head modeling and a standard 10-20 system as electrode montage (19 electrodes). These results represent a reciprocal cross-validation of the two mathematically independent techniques in a clinical environment.
منابع مشابه
High resolution EEG: 124-channel recording, spatial deblurring and MRI integration methods.
This paper describes a method for increasing the spatial detail of the EEG and for integrating physiological data with anatomical models based on magnetic resonance images (MRIs). This method includes techniques to efficiently record EEG data from up to 124 channels, to measure 3-D electrode positions for alignment with MRI-derived head models, and to estimate potentials near the outer convexit...
متن کاملLearning Blind Deconvolution
In this work, we propose a novel prior term for the regularization of blind deblurring methods. The proposed method introduces machine learning techniques into the blind deconvolution process. The proposed technique has sound mathematical foundations and is generic to many inverse problems. We demonstrate the usage of this regularizer within Bayesian blind deconvolution framework, and also inte...
متن کاملImage deblurring and denoising with non-local regularization constraint
In this paper, we investigate the use of the non-local means (NLM) denoising approach in the context of image deblurring and restoration. We propose a novel deblurring approach that utilizes a non-local regularization constraint. Our interest in the NLM principle is its potential to suppress noise while effectively preserving edges and texture detail. Our approach leads to an iterative cost fun...
متن کاملVALUE OF INT ER-ICTAL SURFACE EEG IN THE DIAGNOSIS OF SEIZURE DISORDERS IN CHILDREN: A LOCAL ST UDY
We wished to assess the frequency of EEG positivity with our available EEG technology to compare with those elsewhere. Between April 1996 to February 1997, of patients referred to the Pediatric Neurology Out-patient Clinic for assessment of seizure disorders, 202 randomly selected patients aged 16 months to 17 years (mean 8.96 years) underwent a 10-minute inter-ictal EEG recording using a ...
متن کاملDetection of correlated sources in EEG using combination of beamforming and surface Laplacian methods.
Beamforming offers a way to estimate the solution to the inverse problem in EEG and MEG but is also known to perform poorly in the presence of highly correlated sources, e.g. during binaural auditory stimulation, when both left and right primary auditory cortices are activated simultaneously. Surface Laplacian, or the second spatial derivative calculated from the electric potential, allows for ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Methods of information in medicine
دوره 43 1 شماره
صفحات -
تاریخ انتشار 2004