Pilot Study of Bovine Interdigital Cassetteless Computed Radiography

نویسندگان

  • El-Sayed Ahmed Awad EL-SHAFAEY
  • Takahiro AOKI
  • Mitsuo ISHII
  • Kazutaka YAMADA
چکیده

Twenty-one limbs of bovine cadavers (42 digits) were exposed to interdigital cassetteless imaging plate using computed radiography. The radiographic findings included exostosis, a rough planta surface, osteolysis of the apex of the distal phalanx and widening of the laminar zone between the distal phalanx and the hoof wall. All these findings were confirmed by computed tomography. The hindlimbs (19 digits) showed more changes than the forelimbs (10 digits), particularly in the lateral distal phalanx. The cassetteless computed radiography technique is expected to be an easily applicable method for the distal phalanx rather than a conventional cassette-plate and/or the film-screen cassetteless methods.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Quality comparison of direct digital panoramic radiography and computed radiography panoramic

BACKGROUND AND AIM: Digital panoramic X-ray images can be captured using photostimulable phosphors or solid-state detectors (i.e. charge-coupled devices and Flat-Panels). The first category is defined as computed radiography (CR) or semi-direct radiography. The second technology that uses solid-state detectors is known as direct digital radiography (DDR). Both of these technologies have their o...

متن کامل

Comparing the Accuracy of Cone Beam Computed Tomography,Digital Intraoral Radiography and Conventional Intraoral Radiography in the Measurement of Periodontal Bone Defects

Background and Aim: Cone beam computed tomography (CBCT) produces high-quality data in periodontal diagnosis and treatment planning. The aim of this study was to compare the accuracy of CBCT with intraoral digital and conventional radiography in the measurement of periodontal bone defects.  Methods and Materials: In this diagnostic research, two hundred and eighteen artificial osseous d...

متن کامل

Determination of Diagnostic Reference Level in routine Computed radiography examination in north of Iran

Introduction: Digital radiography has a major role in nowadays healthcare system so radiation protection (justification and optimization) is important in this field. Many related organizations to protection suggested to establish national and regional diagnostic reference level for medical procedures. Reference levels are typically set at the 75th percentile of the dose distri...

متن کامل

Comparison of Diagnostic Accuracy of Cone Beam Computed Tomography and Digital Radiography for Detection of Vertical Root Fractures with and without Gutta Percha

  Objective: Diagnosis of vertical root fractures (VRFs) is critical in endodontics which most of the times occurs in endodontically treated teeth with root canal fillings such as gutta percha. Despite Cone Beam Computed Tomography (CBCT) has significantly enhanced image quality compared to digital radiography (DR) which aid the diagnosis, artifacts has remained as a problem in VRF detection . ...

متن کامل

Development of Computed Tomography Head and Body Phantom for Organ Dosimetry

Introduction: Quality assurance in Computed tomography (CT) centers in developing countries are largely hindered by the unavailability of CT phantoms. The development of a local CT phantom for the measurement of organ radiation absorbed dose is therefore requisite. Material and Methods: Local CT phantoms were designed to meet the standard criteria of 32 cm diameter for body, 16 cm diameter for...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 75  شماره 

صفحات  -

تاریخ انتشار 2013