Impact of valve prosthesis-patient mismatch on pulmonary arterial pressure after mitral valve replacement.

نویسندگان

  • Mingzhou Li
  • Jean G Dumesnil
  • Patrick Mathieu
  • Philippe Pibarot
چکیده

OBJECTIVES We sought to determine the impact of valve prosthesis-patient mismatch (PPM) on pulmonary arterial (PA) pressure after mitral valve replacement (MVR). BACKGROUND Pulmonary arterial hypertension is a serious complication of mitral valve disease, and it is a major risk factor for poor outcome after MVR. We hypothesized that valve PPM might be a determinant of PA hypertension after MVR. METHODS Systolic PA pressure was measured by Doppler echocardiography in 56 patients with normally functioning mitral prosthetic valves. Mitral valve effective orifice area (EOA) was determined by the continuity equation and indexed for body surface area. RESULTS Thirty patients (54%) had PA hypertension defined as systolic PA pressure >40 mm Hg, whereas 40 patients (71%) had PPM defined as an indexed EOA < or =1.2 cm(2)/m(2). There was a significant correlation (r = 0.64) between systolic PA pressure and indexed EOA. The average systolic PA pressure and prevalence of PA hypertension were 34 +/- 8 mm Hg and 19% in patients with no PPM versus 46 +/- 8 mm Hg and 68% in patients with PPM (p < 0.001). In multivariate analysis, the indexed EOA was by far the strongest predictor of systolic PA pressure. CONCLUSIONS Persistent PA hypertension is frequent after MVR and strongly associated with the presence of PPM. The clinical implications of these findings are important given that PPM can largely be avoided by using a simple prospective strategy at the time of operation.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Health-Related Quality of Life after Valve Replacement Surgery

Background: Heart valve disease gradually increases the pressure in the heart chambers and impairs heart pumping. It influences on quality of life due to low output, disability, fear, amnesia, anxiety, and depression. Although most of signs and symptoms in patients with heart valve diseases may significantly decrease after valve replacement surgery, there is limited information about the impact...

متن کامل

Right sided heart evaluation after successful mitral valve replacement.

Introduction: It is well-documented that right-sided heart dysfunction and significant tricuspid valve regurgitation (TVR) have adverse effects on patient outcomes after left-sided heart valve surgery. Therefore, the evaluation of right ventriclular (RV) function and TR severity in patients who had undergone mitral valve replacement (MVR), associated with/without concomitant su...

متن کامل

Impact of prosthesis-patient mismatch on survival after mitral valve replacement.

BACKGROUND We recently reported that valve prosthesis-patient mismatch (PPM) is associated with persisting pulmonary hypertension after mitral valve replacement. Thus, the objective of this study was to evaluate the impact of PPM on mortality in patients undergoing mitral valve replacement. METHODS AND RESULTS The indexed valve effective orifice area was estimated for each type and size of pr...

متن کامل

Does patient-prosthesis mismatch affect long-term results after mitral valve replacement?

BACKGROUND Recently, some articles about patient-prosthesis mismatch (PPM) of the mitral valve have been published. However, the outcome of PPM of the mitral valve remains controversial. The objective of this study was to determine the impact of mitral valve PPM on clinical results after mitral valve replacement (MVR). METHODS AND RESULTS Eighty-four patients underwent MVR from 1992 to 2005. ...

متن کامل

Star GK Bileaflet Mechanical Valve Prosthesis-Patient Mismatch After Mitral Valve Replacement: A Chinese Multicenter Clinical Study

BACKGROUND The aim of this study was to investigate the incidence and immediate and mid-term effects of heart valve prosthesis-patient mismatch (PPM) after mitral valve replacement using the GK bileaflet mechanical valve. MATERIAL AND METHODS A total of 493 cases of mechanical mitral valve replacement were performed in the departments of cardiac surgery in 7 hospitals from January 2000 to Jan...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of the American College of Cardiology

دوره 45 7  شماره 

صفحات  -

تاریخ انتشار 2005