Comparison of real-time three-dimensional gadolinium-enhanced elliptic centric-ordered MR venography and two-dimensional time-of-flight MR venography of the intracranial venous system.

نویسندگان

  • Jui-Hsun Fu
  • Ping-Hong Lai
  • Chia-Chi Hsiao
  • Shang-Chieh Li
  • Mei-Jui Weng
  • Po-Ching Wang
  • Clement Kuen-Huang Chen
چکیده

BACKGROUND To compare 3-dimensional gadolinium-enhanced elliptic centric-ordered (3D GEC) magnetic resonance venography (MRV) with traditional 2-dimensional time-of-flight (2D TOF) MRV for imaging of the intracranial venous system. METHODS Fifty-three patients underwent 2D and 3D MRV, whereby venous structures were evaluated by 2 neuroradiologists. RESULTS Of the 53 patients, 10 were diagnosed with dural venous sinus thrombosis and 12 with intracranial tumors. 3D GEC MRV displayed superior sensitivity/specificity (90.9%/96.8%) compared to 2D TOF MRV (63.6%/48.4%). Analysis of the areas under the receiver operating characteristic curves also showed superiority of 3D GEC (0.91) versus 2D TOF (0.53) MRV. Of the remaining 31 healthy patients, the rate of complete visibility of venous structures was also greater for 3D GEC (95.8%) than for 2D TOF (62.1%) MRV. CONCLUSION 3D GEC MRV is superior to 2D TOF MRV for providing more detail of the intracranial venous system, and can lead to better diagnosis of venous conditions.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Contrast Enhanced Cerebral MR Venography: Comparison between Arterial and Venous Triggering Methods

Purpose : To compare the arterial and venous detection sites of triggering methods in contrast-enhanced-MR-venography (CE-MRV) for the evaluation of intracranial venous system. Materials and Methods: 41 healthy patients underwent CE-MRV with autotriggering at either the cavernous segment of internal carotid artery with an inserted time-delay of 6 seconds (n = 20) or the superior sagittal sinus ...

متن کامل

Partially recanalized chronic dural sinus thrombosis: findings on MR imaging, time-of-flight MR venography, and contrast-enhanced MR venography.

BACKGROUND AND PURPOSE The imaging appearance of chronic, partially recanalized dural sinus thrombosis has been incompletely described. We sought to more fully characterize the imaging findings of this entity on MR imaging, time-of-flight MR venography (TOF-MRV), and elliptic centric-ordered contrast-enhanced MR venography (CE-MRV). MATERIALS AND METHODS From a data base of patients with cere...

متن کامل

Direct contrast-enhanced 3D MR venography evaluation of upper extremity deep venous system.

PURPOSE To investigate the diagnostic value of direct contrast-enhanced three dimensional magnetic resonance (3D MR) venography in mapping the deep venous system of the upper extremities and to plan potential interventional procedures. MATERIALS AND METHODS Nineteen cases with the diagnoses of end-stage renal disease with multiple hemodialysis catheter access were examined. Direct contrast-en...

متن کامل

Time-of-flight intracranial MR venography: evaluation of the sequential oblique section technique.

PURPOSE To implement a time-of-flight MR angiographic technique using the oblique acquisition of thin gradient-echo sections to evaluate the intracranial venous system, and to assess the feasibility of application of this technique in a routine clinical setting. METHODS The MR angiographic technique consisted of a two-dimensional gradient-echo technique with sequential overlapped sections obt...

متن کامل

Evaluation of the intracranial dural sinuses with a 3D contrast-enhanced MP-RAGE sequence: prospective comparison with 2D-TOF MR venography and digital subtraction angiography.

BACKGROUND AND PURPOSE The diagnosis of dural sinus thrombosis is often difficult because of its variable and nonspecific clinical presentation and the overlapping signal intensities of thrombosis and venous flow on conventional MR images and MR venograms. We compared 3D contrast-enhanced magnetization-prepared rapid gradient-echo (MP-RAGE) sequences with 2D time-of-flight (TOF) MR venography, ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of the Chinese Medical Association : JCMA

دوره 73 3  شماره 

صفحات  -

تاریخ انتشار 2010