A computer method for determining by least squares gamma ray relative intensities using a bent-crystal monochromator

نویسنده

  • Joseph Emerson Brown
چکیده

A method of measuring gamma-ray relative intensities was developed which used a germanium .bent-crystal spectrometer as a monochromator. The response function of a Nai detector to the essentially monoenergetic gamma rays, obtained from the diffracted beam of the spectrometer, was recorded in a multichannel analyzer. The composite spectrum due to all the gamma rays was then recorded in the analyzer. A computer program was written to normalize the response functions to unit area and to determine, by minimizing the sum of the squares of the deviations, the linear combination of monoenergetic response functions that best represents the composite spectrum. The intensity of a gamma ray is then proportional to the adjusted area under the monoenergetic response function. The relative intensities of the gamma rays of Tm 169 obtained by electron capture from Yb 169 were measured.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Fundamental Parameters Approach to X-ray Line-Profile Fitting

A convolution approach to X-ray powder line-profile fitting is developed in which the line shape is synthesized from the Cu Ks emission profile, the dimensions of the diffractometer and the physical variables of the specimen. In addition to the integrated intensities and 20 positions of the line profiles, the parameters that may be fitted include the receiving-slit width, the receiving-slit len...

متن کامل

Characterization of a bent Laue double-crystal beam-expanding monochromator

A bent Laue double-crystal monochromator system has been designed for vertically expanding the X-ray beam at the Canadian Light Source's BioMedical Imaging and Therapy beamlines. Expansion by a factor of 12 has been achieved without deteriorating the transverse coherence of the beam, allowing phase-based imaging techniques to be performed with high flux and a large field of view. However, preli...

متن کامل

Bent-crystal monochromators for high-energy synchrotron radiation.

Two kinds of monochromators covering the energy ranges 100-150 keV and approximately 300 keV have been designed for inelastic (Compton) scattering experiments at the elliptical multipole wiggler beamline, BL08W, of SPring-8. Finite-element analyses using ANSYS for bent crystals indicate that thermal problems are not serious for the 300 keV monochromator, while an energy spread of about 10(-3) f...

متن کامل

LEAST – SQUARES METHOD FOR ESTIMATING DIFFUSION COEFFICIENT

Determining the diffusion coefficient based on the solution of the linear inverse problem of the parameter estimation by using the Least-square method is presented. A set of temperature measurements at a single sensor location inside the heat conducting body is required. The corresponding direct problem will be solved by an application of the heat fundamental solution.

متن کامل

Development of a bent Laue beam-expanding double-crystal monochromator for biomedical X-ray imaging

The Biomedical Imaging and Therapy (BMIT) beamline at the Canadian Light Source has produced some excellent biological imaging data. However, the disadvantage of a small vertical beam limits its usability in some applications. Micro-computed tomography (micro-CT) imaging requires multiple scans to produce a full projection, and certain dynamic imaging experiments are not possible. A larger vert...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2016