Randomised controlled trial of thermostatic mixer valves in reducing bath hot tap water temperature in families with young children in social housing: A protocol

نویسندگان

  • Denise Kendrick
  • Jane Stewart
  • Carol Coupland
  • Michael Hayes
  • Nick Hopkins
  • Debbie McCabe
  • Robert Murphy
  • George O'Donnell
  • Ceri Phillips
  • David Radford
  • Jackie Ryan
  • Sherie Smith
  • Lindsay Groom
  • Elizabeth Towner
چکیده

BACKGROUND Each year in the UK 2000 children attend emergency departments and 500 are admitted to hospital following a bath water scald. The long term effects can include disability, disfigurement or psychological harm and repeated skin grafts may be required as the child grows. The costs of treating a severe scald are estimated at 250,000 GBP. Children living in the most deprived wards are at greatest risk of thermal injuries; hospital admission rates are three times that for children living in the least deprived wards.Domestic hot water, which is usually stored at around 60 degrees Celsius, can result in a second-degree burn after 3 seconds and a third-degree burn after 5 seconds. Educational strategies to encourage testing of tap water temperature and reduction of hot water thermostat settings have largely proved unsuccessful. Legislation in the USA mandating pre-setting hot water heater thermostats at 49 degrees Celsius was effective in reducing scald injuries, suggesting passive measures may have a greater impact. Thermostatic mixer valves (TMVs), recently developed for the domestic market, fitted across the hot and cold water supply pipes of the bath, allow delivery of water set at a fixed temperature from the hot bath tap. These valves therefore offer the potential to reduce scald injuries. DESIGN/METHODS A pragmatic, randomised controlled trial to assess the effectiveness of TMVs in reducing bath hot tap water temperatures in the homes of families with young children in rented social housing. Two parallel arms include an intervention group and a control group where the intervention will be deferred.The intervention will consist of fitting a TMV (set at 44 degrees Celsius) by a qualified plumber and provision of educational materials. The control arm will not receive a TMV or the educational materials for the study duration but will be offered the intervention after collection of follow-up data 12 months post randomisation.The primary outcome measure will be the bath hot tap water temperature. Fifteen families per arm are required to detect a reduction in the mean bath hot tap water temperature from 60.4 degrees Celsius (SD 9.1) in the control group to 46 degrees Celsius in the intervention group, with 90% power and a 5% significance level (2 sided). Secondary outcome measures including acceptability will require a sample size of 120 participants. DISCUSSION Whilst TMVs have the potential to reduce scald injuries, to date there have been no randomised controlled trials assessing their effectiveness, acceptability and cost effectiveness. TRIAL REGISTRATION ISRCTN21179067.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Randomised controlled trial of thermostatic mixer valves in reducing bath hot tap water temperature in families with young children in social housing.

OBJECTIVES To assess the effectiveness of thermostatic mixing valves (TMVs) in reducing bath hot tap water temperature, assess acceptability of TMVs to families and impact on bath time safety practices. DESIGN Pragmatic parallel arm randomised controlled trial. SETTING A social housing organisation in Glasgow, Scotland, UK. PARTICIPANTS 124 families with at least one child under 5 years. ...

متن کامل

Preventing bath water scalds: a cost-effectiveness analysis of introducing bath thermostatic mixer valves in social housing.

AIMS To assess the cost-effectiveness of installing thermostatic mixer valves (TMVs) in reducing risks of bath water scalds and estimate the costs of avoiding bath water scalds. METHODS The evaluation was undertaken from the perspective of the UK public sector, and conducted in conjunction with a randomised control trial of TMVs installed in social housing in Glasgow. Installation costs were ...

متن کامل

Scald risk in social housing can be reduced through thermostatic control system without increasing Legionella risk: a cluster randomised trial.

OBJECTIVE To quantify the effects of a thermostatic control system in social (public) housing on the prevalence of dangerous (>60°C) water temperatures and on fuel consumption. DESIGN Pair-matched double-blind cluster randomised controlled trial. SETTING Social housing in a deprived inner-London borough. PARTICIPANTS 150 households recruited as clusters from 22 social housing estates. Fou...

متن کامل

Patterns of scald injuries.

OBJECTIVES To describe common patterns of bath water scald injuries in children, to examine differences between accidental and non-accidental bath water scalds in children, and to examine potential for prevention. DESIGN A two year six month retrospective analysis of admissions to a specialist burns unit. SETTING The Burns Unit, St Lawrence Hospital, Chepstow serving children from south and...

متن کامل

Independent and Social Living Skills Training for People with Schizophrenia in Iran: a Randomized Controlled Trial

Objectives: Schizophrenia is responsible for a significant proportion of burden of mental diseases in Iran. Lack of a follow-up system has resulted in the repeated hospitalizations. In this study it is hypothesized that standardized living skills training delivered to participants with schizophrenia in outpatient and inpatient centers can be effective compared to a  control group (with occ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Trials

دوره 9  شماره 

صفحات  -

تاریخ انتشار 2008