The treatment of metastasis to the femoral neck using percutaneous hollow perforated screws with cement augmentation.

نویسندگان

  • H G Kang
  • Y W Roh
  • H S Kim
چکیده

We have developed a hollow perforated cannulated screw. One or more of these was implanted percutaneously in 11 patients with an osteolytic metastasis in the femoral neck and multiple metastases elsewhere. They were supplemented by one or two additional standard 6.5 mm cannulated screws in nine patients. Polymethylmethacrylate bone cement was injected through the screw into the neck of the femur using small syringes, as in vertebroplasty. The mean amount of cement injected was 23.2 ml (17 to 30). Radiotherapy was started on the fourth post-operative day and chemotherapy, on average, was resumed a day later. Good structural stability and satisfactory relief from pain were achieved in all the patients. This technique may be useful in the palliation of metastases in the femoral neck.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Implant Augmentation: Adding Bone Cement to Improve the Treatment of Osteoporotic Distal Femur Fractures

The increasing problems in the field of osteoporotic fracture fixation results in specialized implants as well as new operation methods, for example, implant augmentation with bone cement. The aim of this study was to determine the biomechanical impact of augmentation in the treatment of osteoporotic distal femur fractures.Seven pairs of osteoporotic fresh frozen distal femora were randomly ass...

متن کامل

Calcium phosphate cement augmentation of the femoral neck defect created after dynamic hip screw removal.

OBJECTIVE To determine the effect of reinforced calcium phosphate cement augmentation of the femoral neck defect created after dynamic hip screw removal in a cadaveric model. METHODS The lag screws of dynamic hip screw implants were inserted and subsequently removed in 8 matched pairs of cadaveric, osteoporotic femurs to create a femoral neck defect. One of each pair had the defect augmented ...

متن کامل

The PFNA® Augmented in Revision Surgery of Proximal Femur Fractures

OBJECTIVES Modern implants for proximal femur fracture treatment have clearly improved clinical results. However, complications, including cut-out and loss of reduction, requiring revision surgery still occur. A major challenge in these cases is a loss of bone stock due to the existing implant, which is usually exacerbated by osteoporosis. A potential solution is the augmentation of implants, f...

متن کامل

Bilateral Simultaneous Femoral Neck and Shafts Fractures – A Case Report

  Simultaneous fractures of the femoral neck and shaft are not common injuries, though they cannot be considered rare. Herein, we report our experience with a patient with bilateral occurance of this injury. Up to the best of our knowkedge this is the first case reported in literature in which correct diagnosis was made initially. Both femurs were fixed using broad 4.5 mm dynamic compression pl...

متن کامل

Percutaneous Cement-Augmented Screws Fixation in the Fractures of the Aging Spine: Is It the Solution?

INTRODUCTION Management of elderly patients with thoracolumbar fractures is still challenging due to frequent osteoporosis and risk of screws pull-out. The aim of this study was to evaluate results of a percutaneous-only procedure to treat these fragile patients using cement-augmented screws. METHODS 12 patients diagnosed with a thoracolumbar fracture associated with an important loss of bone...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of bone and joint surgery. British volume

دوره 91 8  شماره 

صفحات  -

تاریخ انتشار 2009