Fluoroless Catheter Ablation of Cardiac Arrhythmias: A 5-Year Experience.
نویسندگان
چکیده
BACKGROUND Catheter ablations have been traditionally performed with the use of fluoroscopic guidance, which exposes the patient and staff to the inherent risks of radiation. We have developed techniques to eliminate the use of fluoroscopy during cardiac ablations and have been performing completely fluoroless catheter ablations on our patients for over 5 years. METHODS We present a retrospective analysis of the safety, efficacy, and feasibility data from 500 consecutive patients who underwent nonfluoroscopic catheter ablation, targeting a total of 639 arrhythmias, including atrioventricular reciprocating tachycardia (AVRT), atrioventricular nodal reentrant tachycardia (AVNRT), atrial tachycardia (AT), atrial fibrillation (AF), premature ventricular contractions (PVCs), and ventricular tachycardia (VT). We perform fluoroless ablations using intracardiac electrograms, electroanatomic mapping, and for most cases intracardiac echocardiography. Our experience includes exclusively endocardial cardiac ablations. RESULTS The mean follow-up was 20.5 months. Recurrence rate for AVRT was 6.5%, for AVNRT 2.5%, for macro-reentrant AT 6.4%, for focal AT 5.4%, for AF 22.6%, for PVC 6.7%, and for VT 21.4%. Major complications occurred in five patients (1.0%); minor complications occurred in three patients (0.6%). No deaths occurred. Fluoroscopy was used in one instance, for 0.3 minutes, to confirm venous access. CONCLUSIONS Completely fluoroless catheter ablations may be routinely performed for all endocardial ablations without compromising safety, efficacy, or procedural duration.
منابع مشابه
Catheter ablation of atrial fibrillation: do we know what we are doing?
Although atrial fibrillation (AF) represents the most common arrhythmia that is seen in every day cardiology practice, the surgeons, and not the cardiologists, were the first to take the initiative for its radical cure. Cox and colleagues developed the Maze procedure and its modifications in the 80s followed by the pioneering attempt of Swartz et al. to ablate the arrhythmia in the electrophysi...
متن کاملRecurrent torsades de pointes after catheter ablation of incessant ventricular bigeminy in combination with QT prolongation.
A 45-year-old woman, who had received a single-chamber implantable cardioverter defibrillator (ICD) due to ventricular fibrillation 5 years ago, was admitted for catheter ablation of incessant right ventricular outflow tract bigeminy. After successful ablation recurrent torsades de pointes associated with a prolonged corrected QT (QTc) interval were initiated by polymorphic premature ventricula...
متن کاملHow are arrhythmias managed in the paediatric population in Europe? Results of the European Heart Rhythm survey.
The aim of this survey was to provide insight into current practice regarding the management of paediatric arrhythmias in Europe. The survey was based on a questionnaire sent via the Internet to the European Heart Rhythm Association (EHRA) electrophysiology research network centres. The following topics were explored: patient and treatment selection, techniques and equipment, treatment outcomes...
متن کاملCatheter ablation of idiopathic ventricular ectopy in the vicinity of the His bundle under the septal leaflet of the tricuspid valve.
A 59-year-old female with frequent, drug-refractory ventricular premature beats (VPBs) was referred for catheter ablation. On her resting ECG, monomorphic VPBs were present in bigeminic pattern with axis similar to sinus rhythm, transition zone in lead V3 and slurring in leads III, V2, and V3 (Figure 1A). During the procedure, the earliest ventricular activation site was localized just below th...
متن کاملCavo-tricuspid isthmus radiofrequency ablation using a novel remote navigation catheter system in patients with typical atrial flutter.
AIMS A new remote catheter system (AMIGO™ Remote Catheter System) compatible with conventional ablation catheters is now commercially available but no data about its performance in clinical use during ablation have been reported. This study evaluates the feasibility, efficacy, and safety of cavo-tricuspid isthmus (CTI) ablation with this system in patients with typical atrial flutter (AFl). M...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Pacing and clinical electrophysiology : PACE
دوره 40 4 شماره
صفحات -
تاریخ انتشار 2017