Definition of an immunologic response using the major histocompatibility complex tetramer and enzyme-linked immunospot assays.
نویسندگان
چکیده
PURPOSE Define an immunologic response using the tetramer and enzyme-linked immunospot (ELISPOT) assays. EXPERIMENTAL DESIGN Ten healthy subjects and 21 patients with melanoma (all HLA-A*0201) donated a total of 121 blood samples to determine the lower limit of detection (LLD), analytic coefficient of variation (aCV), and physiologic CV (pCV) of the tetramer and ELISPOT assays. The mean, SD, and reference change value (RCV) were calculated to define changes beyond the assay imprecision, and its application was tested in the monitoring of T-cell expansion after CTLA4 blockade with ticilimumab (CP-675,206). RESULTS The LLD for the tetramer assay was 0.038% CD8+ cells and seven spots per 10(5) peripheral blood mononuclear cells for the ELISPOT assay. The aCV of the tetramer assay was <10% and was higher for the ELISPOT (24.69-36.32%). There was marked between-subject variability on baseline homeostatic values, which was correlated to prior antigen exposure. An immunologic response was defined as an increase beyond the mean + 3 SD in antigen-specific cells for subjects with baseline levels below the LLD, or beyond the assay RCV for baseline levels above the LLD. In four patients receiving ticilimumab, expansions of antigen-specific T cells beyond the assay variability were noted for EBV and MART1 antigens. CONCLUSIONS A combined approach of change from negative (below the LLD) to positive (above the LLD) and a percentage change beyond the assay variability using the RCV score can be computed to define which change in circulating antigen-specific T cells represents a response to immunotherapy.
منابع مشابه
Functionally Inert HIV-Specific Cytotoxic T Lymphocytes Do Not Play a Major Role in Chronically Infected Adults and Children
The highly sensitive quantitation of virus-specific CD8(+) T cells using major histocompatibility complex-peptide tetramer assays has revealed higher levels of cytotoxic T lymphocytes (CTLs) in acute and chronic virus infections than were recognized previously. However, studies in lymphocytic choriomeningitis virus infection have shown that tetramer assays may include measurement of a substanti...
متن کاملEnzyme-Linked Immunosorbent Spot Assay for the Detection of Wilms’ Tumor 1-Specific T Cells Induced by Dendritic Cell Vaccination
BACKGROUND Despite recent advances in cancer immunotherapy and the development of various assays for T cell assessment, a lack of universal standards within immune monitoring remains. The objective of this study was to evaluate the enzyme-linked immunosorbent spot (ELISpot) assay in comparison with major histocompatibility complex-tetramer analysis in the context of dendritic cell (DC)-based ca...
متن کاملImmunological Prediction of Cytomegalovirus (CMV) Replication Risk in Solid Organ Transplantation Recipients: Approaches for Regulating the Targeted Anti-CMV Prevention Strategies
The current cytomegalovirus (CMV) prevention strategies in solid organ transplantation (SOT) recipients have contributed towards overcoming the detrimental effects caused by CMV lytic infection, and improving the long-term success rate of graft survival. Although the quantification of CMV in peripheral blood is the standard method, and an excellent end-point for diagnosing CMV replication and m...
متن کاملImmunologic monitoring of cancer vaccine therapy: results of a workshop sponsored by the Society for Biological Therapy.
The Society for Biological Therapy held a Workshop last fall devoted to immune monitoring for cancer immunotherapy trials. Participants included members of the academic and pharmaceutical communities as well as the National Cancer Institute and the Food and Drug Administration. Discussion focused on the relative merits and appropriate use of various immune monitoring tools. Six breakout groups ...
متن کاملValidation of multiparametric tetramer staining Principle of the validation
While the detection of serological response is well described and objects of numerous guidance, much less information is available on validation of methodology for the detection of cellular immunologic response responses. A recently developed approach uses tetrameric complexes of HLA molecules to stain antigen-specific T cells in FACS analysis. Tetramer staining presents advantages over traditi...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Clinical cancer research : an official journal of the American Association for Cancer Research
دوره 12 1 شماره
صفحات -
تاریخ انتشار 2006