Pneumatic-type surgical robot end-effector for laparoscopic surgical-operation-by-wire
نویسندگان
چکیده
BACKGROUND Although minimally invasive surgery (MIS) affords several advantages compared to conventional open surgery, robotic MIS systems still have many limitations. One of the limitations is the non-uniform gripping force due to mechanical strings of the existing systems. To overcome this limitation, a surgical instrument with a pneumatic gripping system consisting of a compressor, catheter balloon, micro motor, and other parts is developed. METHOD This study aims to implement a surgical instrument with a pneumatic gripping system and pitching/yawing joints using micro motors and without mechanical strings based on the surgical-operation-by-wire (SOBW) concept. A 6-axis external arm for increasing degrees of freedom (DOFs) is integrated with the surgical instrument using LabVIEW® for laparoscopic procedures. The gripping force is measured over a wide range of pressures and compared with the simulated ideal step function. Furthermore, a kinematic analysis is conducted. To validate and evaluate the system's clinical applicability, a simple peg task experiment and workspace identification experiment are performed with five novice volunteers using the fundamentals of laparoscopic surgery (FLS) board kit. The master interface of the proposed system employs the hands-on-throttle-and-stick (HOTAS) controller used in aerospace engineering. To develop an improved HOTAS (iHOTAS) controller, 6-axis force/torque sensor was integrated in the special housing. RESULTS The mean gripping force (after 1,000 repetitions) at a pressure of 0.3 MPa was measured to be 5.8 N. The reaction time was found to be 0.4 s, which is almost real-time. All novice volunteers could complete the simple peg task within a mean time of 176 s, and none of them exceeded the 300 s cut-off time. The system's workspace was calculated to be 11,157.0 cm3. CONCLUSIONS The proposed pneumatic gripping system provides a force consistent with that of other robotic MIS systems. It provides near real-time control. It is more durable than the existing other surgical robot systems. Its workspace is sufficient for clinical surgery. Therefore, the proposed system is expected to be widely used for laparoscopic robotic surgery. This research using iHOTAS will be applied to the tactile force feedback system for surgeon's safe operation.
منابع مشابه
Development of Endoscopic Forceps Manipulator Using Multi-slider Linkage Mechanisms
This paper proposes an endoscopic forceps manipulator with 2-DOFs bending mechanism by multi-slider linkage mechanisms and 1-DOF wire-driven grasping mechanism. Careful design of the linkage channels and restoring springs enabled unique, independent and stable bending procedure from −90 to 90 degrees on the horizontal and vertical plane to secure large working space. The manipulator consisted o...
متن کاملCooperative robotic assistant with drill-by-wire end-effector for spinal fusion surgery
Purpose: This research is aimed at developing a surgical robot for spinal fusion and its control framework that provides higher operation accuracy, greater flexibility of robot position control, and improved ergonomics. Design/Methodology/Approach: A human-guided robot for the spinal fusion surgery has been developed with a dexterous end-effector that is capable of high-speed drilling for corti...
متن کاملEnd-effector for Fast Wire Cutting and Crimping on a 4-dof Parallel Robot
This article describes the development of compact and efficient tools exploited by a 4-DOF robot during an automated process aimed at building heating coils. Resistive wires must be cut and crimped into small connectors at a fast pace, with extreme repeatability and reliability. We designed two special tools for the end effector of a parallel-kinematic robotic device. Wire cutting has been obta...
متن کاملOn the Design and Development of a Novel 4-dof Wire- Driven Laparoscopic Surgical Robotic System, “mu- Laparobot”
This paper describes the design and development of a new wire-driven laparoscopic surgical robotic system, “MU-LapaRobot.” The aim of our design is to develop a robotic system to work with traditional surgical tools to reduce the surgeon’s learning curve in using our robotic system. The overall design is strictly based on surgical requirements and superior improvements from available research a...
متن کاملExperimental Characterization and Control of Miniaturized Pneumatic Artificial Muscle
Robotic surgical tools used in minimally invasive surgeries (MIS) require miniaturized and reliable actuators for precise positioning and control of the end-effector. Miniature pneumatic artificial muscles (MPAM) are a good choice due to their inert nature, high force to weight ratio and fast actuation. In this paper, we present the development of a miniaturized braided pneumatic muscles with a...