Pullout of a lumbar plate with varying screw lengths
نویسندگان
چکیده
BACKGROUND Screw length pertains to stability in various orthopedic fixation devices. There is little or no information on the relationship between plate pullout strength and screw length in anterior lumbar interbody fusion (ALIF) plate constructs in the literature. Such a description may prove useful, especially in the treatment of osteoporotic patients where maximizing construct stability is of utmost importance. Our purpose is to describe the influence of screw length on ALIF plate stability in severely and mildly osteoporotic bone foam models. METHODS Testing was performed on polyurethane foam blocks with densities of 0.08 g/cm(3) and 0.16 g/cm(3). Four-screw, single-level ALIF plate constructs were secured to the polyurethane foam blocks by use of sets of self-tapping cancellous bone screws that were 20, 24, 28, 32, and 36 mm in length and 6.0 mm in diameter. Plates were pulled out at 1 mm/min to failure, as defined by consistently decreasing load despite increasing displacement. RESULTS Pullout loads in 0.08-g/cm(3) foam for 20-, 24-, 28-, 32-, and 36-mm screws averaged 303, 388, 479, 586, and 708 N, respectively, increasing at a mean of 25.2 N/mm. In 0.16-g/cm(3) foam, pullout loads for 20-, 24-, 28-, 32-, and 36-mm screws averaged 1004, 1335, 1569, 1907, and 2162 N, respectively, increasing at a mean of 72.2 N/mm. CONCLUSIONS The use of longer screws in ALIF plate installation is expected to increase construct stability. Stabilization from screw length in osteoporotic patients, however, is limited.
منابع مشابه
Insertional torque and pullout strength of pedicle screws with or without repositioning: a porcine study.
PURPOSE. To evaluate the insertion torque and pullout strength of pedicle screws with or without repositioning. METHODS. 20 fresh porcine lumbar vertebrae of similar size were used. The entry point was at the site just lateral and distal to the superior facet joint of the vertebra, and to a depth of 35 mm. A 6.2-mm-diameter, 35-mm-long pedicle screw was inserted parallel to the superior end pla...
متن کاملFlexibility and fatigue evaluation of oblique as compared with anterior lumbar interbody cages with integrated endplate fixation.
OBJECTIVE This study was undertaken to quantify the in vitro range of motion (ROM) of oblique as compared with anterior lumbar interbody devices, pullout resistance, and subsidence in fatigue. METHODS Anterior and oblique cages with integrated plate fixation (IPF) were tested using lumbar motion segments. Flexibility tests were conducted on the intact segments, cage, cage + IPF, and cage + IP...
متن کاملThe Pullout Strength of Pedicle Screws Following Redirection After Lateral Wall Breach or End-plate Breach.
STUDY DESIGN Using fresh cadavers, the biomechanical testing were used to examine the pullout strength of each pedicle screw. OBJECTIVE The aim of this study was to evaluate pullout strength of (1) a redirected pedicle screw following lateral wall breach; (2) a redirected pedicle screw following end-plate breach; and (3) a pedicle without redirection after end-plate breach without redirection...
متن کاملPedicle Screw Fixation Study in Immature Porcine Spines to Improve Pullout Resistance during Animal Testing
The porcine model is frequently used during development and validation of new spinal devices, because of its likeness to the human spine. These spinal devices are frequently composed of pedicle screws with a reputation for stable fixation but which can suffer pullouts during preclinical implantation on young animals, leading to high morbidity. With a view to identifying the best choices to opti...
متن کاملThe Comparison of Pullout Strengths of Various Pedicle Screw Designs on Synthetic Foams and Ovine Vertebrae.
AIM One of the most common problems with transpedicular screws is screw pullout. This study was conducted to measure the pullout strengths of newly designed transpedicular screws. MATERIAL AND METHODS The design of the three group screws were conical cored standard pedicle screw (Type A), dual threaded pedicle screw (Type B), dual core and dual threaded pedicle screw (Type C), respectively. P...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 6 شماره
صفحات -
تاریخ انتشار 2012