Validation of the mobil-O-Graph: 24 h-blood pressure measurement device.
نویسندگان
چکیده
OBJECTIVE Twenty-four-hour blood pressure measurement is of importance not only in the detection of hypertension but also in the detection of blood pressure changes in hypertensive and nonhypertensives over the day to identify, for example, nondipper hypertensives. This study describes the validation of the mobil-O-Graph according to the criteria of the British Hypertension Society (BHS). METHODS For each patient three readings obtained by the mobil-O-Graph were compared with auscultatory sphygmomanometric readings obtained by two trained clinicians. The sphygmomanometric reference measurements were alternated with the readings obtained by the device. Eighty-five patients (mean age 53.4+/-18.4 years) were recruited for the BHS protocol. Differences between blood pressure values of the test device and the mercury reading were calculated for each measurement. RESULTS In the BHS validation procedure the mean differences of the observer readings and the test device were -2.2+/-6.7 (systolic) and -0.6+/-5.6 mmHg (diastolic) for observer 1 and -2.2+/-7.3 mmHg (systolic) and-0.4+/-6.1 mmHg (diastolic) for observer 2. The device achieved grade A for systolic and diastolic blood pressure for both the observers 1 and 2 leading to a final grade A/A. According to the BHS protocol the measurements of the device have to be considered 'very accurate and with no error of clinical relevance'. CONCLUSION The device met the accuracy requirements of the BHS standard and can be recommended for clinical use.
منابع مشابه
The assessment of agreement between non-invasive, near continuous radial blood pressure measurement and conventional ambulatory blood pressure monitoring during night time sleep
The objective of this study was to compare the blood pressure (BP) measurements during night time sleep of a non-invasive, near-continuous, radial BP instrument to a conventional ambulatory blood pressure monitoring (ABPM) device in a field study setting, in which individuals were not controlled for moving. In order to assess the validity of the radial BP meter in a field setting, we carried ou...
متن کاملComparison of Various Blood Pressure Measurement Techniques with Standard Office Based Blood Pressure Mesurement
Introduction: In order to control Hypertension, it is necessary to understand the methods of blood pressure measurement. Recent guidelines emphasize on employing appropriate blood pressure measurement techniques and white coat hypertension. Definition and methods of blood pressure measurement have changed in the American guideline based on SPRINT trial (Systolic Blood Pressure Intervention Tria...
متن کاملThe role of stress on the rise of blood pressure
Background: The virtual rise of blood pressure resulted from stress, that is observed in subjects that are tested in medical centers, can be oftenly corrected by holter. This phenomenon causes such persons not to response to the common anti blood pressure treatments (2). Materials and methods: This descriptive study was conducted 2006-2007 at the heart clinic of Shohadaye–Ashayer hospital in Kh...
متن کاملValidation of the YuWell YE690A upper-arm blood pressure monitor, for clinic use and self-measurement, according to the European Society of Hypertension International Protocol revision 2010.
OBJECTIVE The present study aimed to evaluate the accuracy of the automated oscillometric upper-arm blood pressure monitor YuWell YE690A for blood pressure measurement according to the International Protocol of the European Society of Hypertension revision 2010. PARTICIPANTS AND METHODS Systolic and diastolic blood pressures were measured sequentially in 33 adult Chinese (12 women, 44.2 years...
متن کاملThe validation of one halitosis measuring device (Etiquette checker)
BACKGROUND AND AIM: Various measurement devices are available for detection of halitosis. For epidemiologic studies, it is necessary to use a portable and small device. This study aimed to investigation of correlation between measuring the device (Etiquette checker) with Halimeter. METHODS: One hundred volunteers (students and patients) participated in this study. The amount of volatile sulfur ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Blood pressure monitoring
دوره 15 4 شماره
صفحات -
تاریخ انتشار 2010