Effect of implantable cardioverter/defibrillator lead placement in the right ventricle on defibrillation energy requirements. A combined experimental and clinical study.
نویسندگان
چکیده
OBJECTIVES The effect of implantable cardioverter/defibrillator (ICD) lead placement in the right ventricle (RV) on defibrillation efficacy has not been thoroughly investigated. Therefore, the goal of this combined experimental and clinical study was to evaluate the effect of a septal and a non-septal position of the right ventricular endocardial spring lead on defibrillation energy. METHODS In 12 isoflurane-anaesthetized swine and subsequently in 8 patients who underwent ICD implantation, two different positions of the distal spring lead in the RV were investigated in randomized order: non-septal position (free wall of the RV) and septal position (interventricular septum). For each position, separate 50% probability determinations of energy (E50), peak voltage (V50) and peak current (A50) were calculated using the three reversal up/down defibrillation procedure. The E50, V50, A50 and impedance (I) were averaged and compared using the two-sided t-test for paired samples. RESULTS Both the experimental study and the clinical study demonstrated that placing the distal defibrillation lead near to the septum rather than near to the ventricular free wall resulted both in the swine and in the patients in significantly lower E50-31.6%/ - 37.1%, V50-16.1%/-20.9% and A50 -10.0%/ - 24.2%, respectively. Defibrillation impedances were significantly reduced only in the experimental study. CONCLUSIONS Defibrillation efficacy depends on the position of the distal spring electrode in the RV. A septal position significantly reduces the energy requirements compared to a non-septal position. The decrease in energy requirements might be explained by an increase in current flow through the septum and the posterolateral wall of the left ventricle. reserved
منابع مشابه
THE EFFECT OF NURSE-PEER-LED SUPPORT INTERVENTION ON QUALITY OF LIFE IN PATIENTS WITH AN IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR: A RANDOMIZED CLINICAL TRIAL
Background & Aims: Nowadays, the quality of life and how coping and treatment of patients with an implantable cardiac defibrillator has led to concern and attempts to reduce or eliminate the problems of these patients in the people who provide health care services. This study aimed to determine the effect of nurse-peer-led support intervention on quality of life in patients with an implantable ...
متن کاملBiventricular Defibrillation with Sequential Shocks Using Patient-derived Computational Models
Standard transvenous defibrillation is performed with implantable cardioverter defibrillators (ICD) using a dualcurrent pathway. The defibrillation energy is delivered from the right ventricle (RV) electrode to the superior vena cava (SVC) electrode and the ICD metallic housing. Clinical studies of biventricular defibrillation, which uses an additional electrode, placed on the left ventricular ...
متن کاملElevated Defibrillation Threshold: Are Defibrillation Vectors Important?
The evaluation of the defibrillation threshold (DFT) is common after the implantation of implantable cardioverter defibrillator (ICD) devices. The goal of this standard of care is to achieve successful defibrillation of ventricular fibrillation. In patients with elevated defibrillation thresholds, alternative techniques are required to correct the situation. We describe a case in which an uncom...
متن کاملAzygos Vein Lead Implantation For High Defibrillation Thresholds In Implantable Cardioverter Defibrillator Placement
Evaluation of defibrillation threshold is a standard of care during implantation of implantable cardioverter defibrillator. High defibrillation thresholds are often encountered and pose a challenge to electrophysiologists to improve the defibrillation threshold. We describe a case series where defibrillation thresholds were improved after implanting a defibrillation lead in the azygos vein.
متن کاملImplantation of a Resynchronization Implantable Cardioverter Defibrillator in a Patient with Persistent Left Superior Vena Cava
Implantation of resynchronization implantable cardioverter defibrillator was performed in a patient with persistent left superior vena cava. A dual coil defibrillation lead was inserted in the right ventricle apex via a small innominate vein. Left ventricular and atrial leads were implanted through persistent left superior vena cava. Left ventricular lead was easily implanted into the postero l...