Brain Source Imaging in Preclinical Rat Models of Focal Epilepsy using High-Resolution EEG Recordings

نویسندگان

  • Jihye Bae
  • Abhay Deshmukh
  • Yinchen Song
  • Jorge Riera
چکیده

Electroencephalogram (EEG) has been traditionally used to determine which brain regions are the most likely candidates for resection in patients with focal epilepsy. This methodology relies on the assumption that seizures originate from the same regions of the brain from which interictal epileptiform discharges (IEDs) emerge. Preclinical models are very useful to find correlates between IED locations and the actual regions underlying seizure initiation in focal epilepsy. Rats have been commonly used in preclinical studies of epilepsy; hence, there exist a large variety of models for focal epilepsy in this particular species. However, it is challenging to record multichannel EEG and to perform brain source imaging in such a small animal. To overcome this issue, we combine a patented-technology to obtain 32-channel EEG recordings from rodents and an MRI probabilistic atlas for brain anatomical structures in Wistar rats to perform brain source imaging. In this video, we introduce the procedures to acquire multichannel EEG from Wistar rats with focal cortical dysplasia, and describe the steps both to define the volume conductor model from the MRI atlas and to uniquely determine the IEDs. Finally, we validate the whole methodology by obtaining brain source images of IEDs and compare them with those obtained at different time frames during the seizure onset.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Localisation of Focal Epileptic Activity in Children Using High Density EEG Source Imaging*

In children suffering from epilepsy, a better understanding of the brain networks involved in epileptic activity is of great clinical and scientific importance. Non-invasive mapping of the epileptic focus can be performed with EEG source imaging (ESI), a technique based on scalp EEG recordings to estimate the localisation of the intra-cerebral electric sources. Recent technological development ...

متن کامل

Automated Non-Invasive Identification and Localization of Focal Epileptic Activity by Exploiting Information Derived from Surface EEG Recordings

Non-invasive epileptic source localization techniques, relying on interictal activity in the EEG and mainly motivated by the need for presurgical localization of the epileptic focus in intractable focal epilepsy, have been widely studied and validated (Blume et al., 2001; Ebersole, 2000; Gavaret et al., 2009; Lantz et al., 2003; Michel et al., 2004; Zumsteg et al., 2005, 2006). Source localizat...

متن کامل

Morphometric MRI Analysis Based on High Resolution 3D Imaging at 7 Tesla Highlightes Focal Cortical Dysplasia in Epilepsy

INTRODUCTION Very high field strength of 7T has mainly been used for methodological or basic scientific studies. So far, very few studies have evaluated the clinical gain of the increased field strength. High field data show an increased signal to noise ratio but they may be compromised by stronger inhomogeneity, varying contrast, or increased susceptibility losses. In many epilepsy patients, t...

متن کامل

Types of Epilepsies and Findings EEG- LORETA about Epilepsy

Neural activity in the human brain starts from the early stages of prenatal development. This activity or signals generated by the brain are electrical in nature and represent not only the brain function but also the status of the whole body. At the present moment, three methods can record functional and physiological changes within the brain with high temporal resolution of neuronal interactio...

متن کامل

Significance of MEG in Presurgical Epilepsy Evaluation

Magnetoencephalography (MEG), as a non-invasive procedure, records magnetic fields generated by spontaneous or evoked brain activity. Presurgical evaluation of pharmacoresistent patients with focal epilepsy is currently the most frequent diagnostic application. The source of epileptic or averaged evoked activity is localised and then overlaid onto magnetic resonance imaging (MRI) of the patient...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 33  شماره 

صفحات  -

تاریخ انتشار 2015