Analysis of published data for top concentration considerations in mammalian cell genotoxicity testing.

نویسندگان

  • James M Parry
  • Elizabeth Parry
  • Pascal Phrakonkham
  • Raffaella Corvi
چکیده

The ability of the in vitro mammalian cell tests currently used to identify genotoxins has been shown to be limited by a high rate of false-positive results, triggering further unnecessary testing in vivo. During an European Centre for the Validation of Alternative Methods workshop on how to improve the specificity of these assays, testing at high concentrations was identified as one possible source of false positives. Thus far, Organisation for Economic Co-operation and Development genotoxicity test guidelines have required testing of chemicals using mammalian cells in vitro should be undertaken to concentrations as high as 10 mM (5000 μg/ml). Recently, a draft revision of the International Conference on Harmonisation of Technical Requirements for Registration of Pharmaceuticals for Human Use genotoxicity test guidelines has recommended that testing concentrations should be reduced to 1 mM (500 μg/ml). To assess the impact that this lowering would have on the outcome of in vitro genotoxicity testing, we established a database of 384 chemicals classified as rodent carcinogens and reported Ames test results and the test concentrations that produced positive results in the mouse lymphoma assay (MLA), in vitro chromosome aberration (CA) assay and in vitro micronucleus test. Genotoxicity testing results were illustrated for 229 and 338 compounds in the MLA and in vitro CA assay, respectively. Of these test compounds, 62.5% produced positive results in the MLA, of which 20.3% required testing between 1 and 10 mM. A total of 58.0% produced positive results in in vitro CA assays, of which 25.0% required testing between 1 and 10 mM. If the testing concentration limit for mammalian cell assays was reduced to 1 mM, 24 (6.25%) potential carcinogens would not be detected in any part of the standard in vitro genotoxicity test battery (Ames test, MLA and in vitro CA assay). Further re-evaluation and/or retest of these compounds by Kirkland and Fowler [Kirkland, D. and Fowler, P. (2010) Further analysis of Ames-negative rodent carcinogens that are only genotoxic in mammalian cells in vitro at concentrations exceeding 1 mM, including retesting of compounds of concern. Mutagenesis 25, 539-553] suggest that the current 10 mM top concentration can be reduced without any loss of sensitivity in detecting rodent carcinogens.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Further analysis of Ames-negative rodent carcinogens that are only genotoxic in mammalian cells in vitro at concentrations exceeding 1 mM, including retesting of compounds of concern.

In the analysis by Parry et al. [Parry, J. M., Parry, E., Phrakonkham, P. and Corvi, R. (2010) Analysis of published data for top concentration considerations in mammalian cell genotoxicity testing. Mutagenesis, 25, 531-538], 24 rodent carcinogens that were negative in the Ames test were identified that were only positive in mammalian cell tests at concentrations between 1 and 10 mM. These carc...

متن کامل

Can in vitro mammalian cell genotoxicity test results be used to complement positive results in the Ames test and help predict carcinogenic or in vivo genotoxic activity? I. Reports of individual databases presented at an EURL ECVAM Workshop.

Positive results in the Ames test correlate well with carcinogenic potential in rodents. This correlation is not perfect because mutations are only one of many stages in tumour development. Also, situations can be envisaged where the mutagenic response may be specific to the bacteria or the test protocol, e.g., bacterial-specific metabolism, exceeding a detoxification threshold, or the inductio...

متن کامل

Induction of micronucleus and abnormal sperm cells in albino mice exposed to ciprofloxacin

The mammalian in vivo micronucleus and sperm morphology assays are widely used as part of the battery of assays for genotoxicity testing required during the development of new drugs. Genotoxicity data on Ciprofloxacin in mammalian system are very limited and mostly contradictory. This study provides more data by assessing the genotoxic potential of ciprofloxacin using mouse micronucleus and spe...

متن کامل

FORUM SERIES Genetic Toxicity Assessment: Employing the Best Science for Human Safety Evaluation Part III: The Comet Assay as an Alternative to In Vitro Clastogenicity Tests for Early Drug Candidate Selection

Early screening of drug candidates for genotoxicity typically includes an analysis for mutagenicity in bacteria and for clastogenicity in cultured mammalian cells. In addition, in recent years, an early assessment of photogenotoxicity potential has become increasingly important. Also, for screening purposes, expert computer systems can be used to identify structural alerts. In cases where struc...

متن کامل

The Cosmetics Europe strategy for animal-free genotoxicity testing: project status up-date.

The Cosmetics Europe (formerly COLIPA) Genotoxicity Task Force has driven and funded three projects to help address the high rate of misleading positives in in vitro genotoxicity tests: The completed "False Positives" project optimized current mammalian cell assays and showed that the predictive capacity of the in vitro micronucleus assay was improved dramatically by selecting more relevant cel...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Mutagenesis

دوره 25 6  شماره 

صفحات  -

تاریخ انتشار 2010